Catalogue excerpts

Lined Mechanical Seal Process Centrifugal Pumps UCL lined PFA End Suction - Back pull-out design CSS-35 Single Mechanical Seal Comply to : 2006/42/CE Design to : EN 22858 / ISO 2858 (ex DIN 24256) ISO 5199 ATEX 100 Directive 94/9/EC Flanged UNI 1092-2 (ISO 7005-2 ) PN16 RF type B slotted ANSI 150 RF CDC-35 Double Cartridge Mechanical Seal Plastic and Fluoroplastic Lined Process Horizontal - Single Stage - Centrifugal pumps with Mechanical Seal Lining: PP (Polypropylene), PVDF (Polyvinylidene fluoride), PFA (Perfluoroalkoxy) Long-coupled and Close-coupled executions

 Open the catalogue to page 1

Mechanical seal arrangement The lined shaft seal chamber with its Long- coupled execution Back pull--out design conical design can accommodate the Pumps use the back pull-out following mechanical seal types : principle and a strong bearing Suitable for handling corrosive, aggressive and hazardous liquids (low viscosity, clean or slightly to dirty contaminated) in the chemical, petrochemical and pharmaceutical industries. housing with flexible coupling CSS-35 Single mechanical seal CDC-35 Double cartridge mechanical seal Single-acting and double-acting mechanical seals configuration, also on cartridge...

 Open the catalogue to page 2

3D VIEW Rigid shaft made of corrosion resistant stainless steel minimizes the shaft deflection < 0,05 mm : the design is in “dry shaft execution” where there is no contact between shaft and medium. The bearing frame can be equipped with 3 different type of • CSS-35 Single mechanical seal • CDC-35 Double cartridge mechanical seal • Single-acting and double-acting mechanical seals configuration, also on cartridge execution All PFA components are made through Transfer Moulding process. The Transfer Moulding process is also employed for PVDF\PP casing and seal chambers. All the UCL pumps can be equipped...

 Open the catalogue to page 3

FEATURES LINED SEAL CHAMBER LINED CASING The ductile cast iron armour protects the fluoroplastic peripheral Wide conical design equipped with breaking ribs. surfaces of the pump from pipe strain, vibration, external shocks and Available in PFA,PVDF or PP lined execution and in a during the handling; moreover it allows the casing to be Vacuum conical shape . The conical seal chamber is designed to push away Top centerline discharge for air handling, self-venting. from the seal solids and slurry, back into the flow path Draining casing (optional). of the process liquid. Self-venting, Self-flushing,...

 Open the catalogue to page 4

MECHANICAL SEAL • • Wide choice of sealing arrangements for maximum sealing flexibility. The CDR mechanical seals have been developed for difficult operating conditions, hazardous and corrosive medium. CSS-35 Single mechanical seal CDC-35 Double cartridge mechanical seal Other mechanical seals can be adapted on UCL pumps, from single seal up to double CSS-35 SINGLE INTERNAL SEAL TAPERED SEAL CHAMBER Available also as CSS-35Q (PLAN62) CDC- 35 DOUBLE CARTRIDGE SEAL TAPERED SEAL CHAMBER Applications where no leakage can be tolerated e.g. hazardous, Easy maintenance thanks to the toxic, inflammable...

 Open the catalogue to page 5

FEATURES BEARING BRACKET FOR LOMG COUPLED EXECUTION Extra-Large Oil Sump design allows to get a large oil capacity. Breather / filling plug on top . Oil sight glass grants a proper oil level. Large drain plug. The bearing frame can be equipped with 3 different type of protections : • Labyrinth seal Non-contacting labyrinth seal Constant level oiler (as an option). Conditions monitoring (as an option). BEARINGS Heavy duty ball bearings configuration to provide L10 bearing life in excess of 17,500 hours (up to 1.25 QBEP). Frontal (impeller side) : one row roller bearings type with high radial load...

 Open the catalogue to page 6

UCL : LONG COUPLED EXECUTION UCL-B : CLOSE COUPLED EXECUTION SECTIONAL DRAWING Temperature range Allowable Pressure Range Flange Connections Viscosity UCL : 1,1 kW (size 80) -> 25 kW (size 200) UCL-B : 1,1 kW (size 90) -> 18.5 kW (size 160) PP : PVDF :   PFA : PN16 (20 °C) UNI 1092-2 / ISO 7005-2 PN 16, type B slotted ANSI 150 PP lined \ PVDF lined \ PFA lined Technical Specifications Electric Motors Suction Casing PP llined \ PVDF lined \ PFA lined Bearing Bracket O-Ring (Shaft Sleeve) O-Ring (Casing) Seal Chamber PP lined \ PVDF lined \ PFA lined

 Open the catalogue to page 7

PERFORMANCE FIELDS closed impeller Closed impellers are indicated to be used with clean liquids. They have a good hydraulic efficiency and there’s no recirculation between the blade’s planes, granting same performances and reliability Not binding data refers to water at room temperature. For specific performance curve contact CDR Pompe SpA.

 Open the catalogue to page 8

PERFORMANCE FIELDS open radial impeller Semi open (Radial) are indicated to be used with dirty liquids. They have a low hydraulic efficiency and there’s recirculation between the blade’s plane Not binding data refers to water at room temperature. For specific performance curve contact CDR Pompe SpA.

 Open the catalogue to page 9

Pump Model Pump Model Pump Model *for UCL-B serie 125/160 eqquipped with motor frame 160: H=208 * L4 dimension is according to installed motor manufacturer Motor Size

 Open the catalogue to page 10

OVERALL DIMENSIONS UCL : Baseplate installation Motor Size 90 Pump model Motor size * L4 dimension is according to installed motor manufacturer

 Open the catalogue to page 11

For further info, please visit www.cdrpompe.com Pompe S.P.A. C.D.R. Pompe S.p.A. Via P. Togliatti, 26/A - 20030 Senago (MI) - Italy Tel. +39029901941 Technical Characteristics The technical data and characteristics stated in this General Catalogue are not binding. CDR Pompe S.p.a. reserves the right to make modifications without notice. Therefore data, dimensions, performances and any other stated issues are indicative only and not binding. Anyway for any technical details you must require an up-to-date product technical card.

 Open the catalogue to page 12

All C.D.R. Pompe catalogues and technical brochures

  1. UCS / UCS-B

    8 Pages

    En
  2. UTS

    12 Pages

    En
  3. UTN-L / UTN-BL

    12 Pages

    En
  4. UCN-L / UCN-BL

    12 Pages

    En
  5. STN series

    8 Pages

    En
  6. HTS series

    4 Pages

    En
  7. ETN series

    8 Pages

    En
  8. ETS series

    8 Pages

    En
  9. HTN

    4 Pages

    En

Archived catalogues