Catalog excerpts
Technical Data Sheet
Open the catalog to page 1CITSens Bio Available SensorsScreen Printed Electrode (SPE) with Immobilized EnzymeDelivery Dimension (SPE) Analytes Gamma irradiated (25 kGy), double packed Length: Tip Diameter: Thickness: Glucose Measuring range Precision Resolution Lactate Measuring range Precision Resolution
Open the catalog to page 2CITSens MeMo Available Sensors 8 01 /2 7 Screen Printed Electrode (SPE) 01 r2 nte Wi ble Gamma irradiated (25 kGy), double packed ila a Av Length: 230 mm or 330 mm Tip Diameter: Thickness: Glucose / Lactate combined Glucose Measuring range 0 - 30 mmol/L Precision +/- 0.1 mmol/L Resolution 0.1 mmol/L Measuring range 0 - 15 mmol/L Precision +/- 0.1 mmol/L Resolution 0.1 mmol/L Glucose / Glutamate combined Glucose Measuring range 0 - 30 mmol/L Precision +/- 0.1 mmol/L Resolution 0.1 mmol/L Glutamate pH pH Measuring range 4 – 9 pH Precision +/- 0.1 pH Resolution 0.05 pH
Open the catalog to page 3The PG 13.5 Sensor is the best choice for any stirred bioreactors. Through the shape based on a standard pH-probe the PG 13.5 Sensor is easily integradeable to any stirred bioreactor via lid or side port. Using PEEK as main in process material the PG 13.5 sensor provides a high biosafety grade to not affect your culture's behaviour. Sensor specifications: Length: Material: In Process Time: Glucose: Lactate: Glutamate: 3002-521.1 CITSens MeMo Glu / Lac Combi Sensor, PG 13.5, long (-300mm) 6 3 Weeks
Open the catalog to page 4Polymer Coated Sensor The Polymere Coated Sensor is the best choice for any static cultivation. Using a polymere coating instead of PEEK materials makes the sensor capable to measure in small voluminas in almost every kind of reactor. Through the elasticity of the screen printed electrode in combination with the polymer coating makes the sensor to our first choice when developing a customized solution. Sensor specifications: Material: Polymer (USP Class VI) Weeks Weeks On request CITSens MeMo Glu / Lac Combi Sensor, PG 13.5, long (-300mm)
Open the catalog to page 5Cap Sensor The Cap Sensor is the best choice for long therm monitoring in agitated environments where the PG 13.5 Sensor is not suitable. Using PEEK as main in process material the Cap Sensor provides a high biosafety grade to not affect your culture's behaviour. Sensor specifications: Length: Material: In Process Time: Glucose: Lactate: Glutamate: CITSens MeMo Glu / Lac Combi Sensor, Cap Sensor, long (-300mm) C-CIT Sensors AG TechSheetBio_V 1
Open the catalog to page 6All C-CIT Sensors AG catalogs and technical brochures
-
CITSens Ion
13 Pages
-
CITSensIon product catalog
16 Pages