Cat Generator Sets Ratings Guide - 20 Pages
15
GAS
50 Hz
CAT 50 Hz CONTINUOUS
GAS RATINGS, 1606 kVA - 8150 kVA
CAT 50 Hz CONTINUOUS CHP
GAS RATINGS, 1380 kVA - 2500 kVA
kVA
1500 rpm
–
–
1944
1944
1975
1986
–
–
2438
2458
–
–
–
–
–
–
–
–
Natural
Gas
G3606
G3606
G3516C IM*
G3516C
G3516C
G3516C
G3608
G3608
G3520C
G3520C IM*
G3612
G3612
G3612
G3612
G3616
G3616
G3616
G16CM34
Low Energy
Gas
–
–
–
–
–
–
–
–
–
G3520C†, ††, †††
–
–
–
–
–
–
–
–
Propane
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
kVA
1000 rpm
1606
1712
–
–
–
–
2143
2281
–
–
3212
3425
3593
3625
4281
4562
4825–
kVA
750 rpm
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
8150
kVA
1500 rpm
1380
1456
2000
2500
2500
Natural
Gas
G3516B
G3516B
G3516E
G3520C
G3520E
Low Energy
Gas
–
–
–
–
–
Propane
–
–
–
–
–
kVA
1000 rpm
–
–
–
–
–
GAS 50 Hz
14
CAT 50 Hz CONTINUOUS
GAS RATINGS, 80 kVA - 1431 kVA
kVA
1500 rpm
80
83
87
106
129
133
138
156
156
200
205
215
350
450
450
600
619
620
631
637
906
931
962
963
1000
1200
1218
1287
1287
1356
1380
1431
Natural
Gas
–
–
G3306 NA
G3306 NA
–
–
G3306 TA
G3306 TA
G3406 NA
G3406 TA
–
–
G3412 TA
G3412C LE
4006-23TR
G3508 LE
G3508 LE
4008-30TR52
G3508 LE
G3508 LE
G3512 LE
G3512 LE
–
G3512 LE
G3512E
G3512E
G3516 TA
G3516 TA
G3516 LE
G3516B
G3516B
G3516B
Low Energy
Gas
G3306 NA†††
G3306 NA†††
–
–
G3406 NA†††
G3406 NA†††
–
–
–
–
G3412 NA†††
G3412 NA†††
–
–
4006-23TR
–
–
4008-30TR52
–
–
–
–
G3512 LE†, †††
–
–
–
–
–
G3516 LE†, ††
–
–
–
Propane
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
kVA
1000 rpm
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
*IM Island Mode
† Landfill
†† Coal Mine Methane
††† Non-Landfill Biogas
-
P. 1
-
P. 4
5DIESEL50 HzCAT 50 Hz DIESEL RATINGS, 2200 kVA - 17463 kVAPrime24253250485065001963260039255200–––––––––––Continuous220029384400587517752363355047256988931334564656523865507638872598251309417463Configuration–––––––––––––––––––––Generator... -
P. 5
7DIESEL60 HzCAT 60 Hz DIESEL RATINGS, 275 ekW - 3100 ekWPrime275275320320365365410455–50054559163568072591010001135127513601360160018251825–225027252825*Continuous–––––––––––––––8308901010123012301230145016401650–205025002600*ConfigurationEPA... -
P. 6
9DIESELrental power ratingsCAT 60 Hz RENTAL POWER RATINGS, 18 ekW - 2000 ekWPrime1827415470901582102753655459109109101825Continuous–––––––––––––––ConfigurationEPA... -
P. 7
11DIESELratings definitionsPrime PowerOutput available with varying load for an unlimited time. Averagepower output is 70% of the prime power rating. Typical... -
P. 8
CAT GENERATOR SETSgas -
P. 9
-
P. 10
17GAS60 HzCAT 60 Hz CONTINUOUSGAS RATINGS, 150 kW - 820 kWkW1800 rpm150177190191350–––375375––––––––––––––––––––NaturalGasG3406... -
P. 11
19GASratings definitionsCAT GAS RATING DEFINITIONSStandby PowerThese ratings are applicable for supplying continuous electricalpower (at variable load)... -
P. 12
CONVERSIONSratings guide -
P. 13
23CONVERSIONSELECTRICAL TABLESSingle-PhaseV x I x P.F.1000V x I1000kW.746 x EFF. (Gen)HP x .746EFF. (Mot.)HP x .746V x P.F. x EFF.kW x 1000V x P.F.kVA... -
P. 14
25CONVERSIONSREDUCED VOLTAGE STARTERSType of StarterFull Voltage StarterAuto Transformer• 80% Tap• 65% Tap• 50% TapResistor StarterSingle... -
P. 20