Fieldbuses
6Pages

{{requestButtons}}

Catalog excerpts

Fieldbuses - 1

CARLO GAVAZZI Automation Components

Open the catalog to page 1
Fieldbuses - 2

Fieldbus DuplineSafe DuplineSafe is based on the Dupline® fieldbus, a system that has been used in more than 120,000 installations worldwide in the harshest industrial environments. Dupline® is particularly known for its reliability, simplicity and ability to transmit signals over long distances – all of which are features required in safety-related systems. The trend is clear – big advantages can be achieved using bus communication in safety related systems. Compared to the traditional serial wiring of NC safety switches, the diagnostics is vastly improved. The immediate indication of...

Open the catalog to page 2
Fieldbuses - 3

Along bulk material conveyors in mines, tunnels, cement factories etc. there are several emergency stop switches connected to a pull-wire, enabling the workers to stop the belt at any point in case of an emergency situation or a fault on the belt. In order to reduce costly downtime of the belt, it is important that the location and nature of the problem is identified as fast as possible. The traditional wiring solution with serial connection of all the safety switches does not provide this diagnostics, it merely stops the belt. Parallel wiring can provide the diagnostics, but it is a...

Open the catalog to page 3
Fieldbuses - 4

CARLO GAVAZZI Motor to be extended, it is easy to install additional input modules. In the machine room, a DuplineSafe relay output module is continuously monitoring the bus and the status of all the safety switches. If one of the safety switches is activated, or if a bus fault is detected, the output module will deactivate its safety relay and thereby stop the belt. The status of the safety switches can be monitored from an HMI or LED mimic panel, providing fast and precise diagnostics. The signals can also be monitored from a PLC or PC, for example by using the Profinet Gateway. CARLO...

Open the catalog to page 4
Fieldbuses - 5

CARLO GAVAZZI DuplineSafe - Safety relay output module DuplineSafe - Input module • Approved by TUV Rheinland Group according to IEC/EN 61508-SIL3, IEC/ EN 62061-SIL3 and ISO/EN 13849-1 PL e • Monitors up to 63 safety input modules • Automatic or manual restart • Status output for external equipment • Easy configuration and testing with handheld programming tool • For mounting on DIN-rail (EN50022) • 230 VAC power supply • cULus approved • Approved by TUV Rheinland Group according to IEC/EN 61508-SIL3, IEC/ EN 62061-SIL3 and ISO/EN 13849-1 PLe • Powered by the bus • Single input for...

Open the catalog to page 5
Fieldbuses - 6

FRANCE Carlo Gavazzi Sarl Zac de Paris Nord II, 69, rue de la Belle Etoile, F-95956 Roissy CDG Cedex Tel: +33 1 49 38 98 60 Fax: +33 1 48 63 27 43 french.team@carlogavazzi.fr OUR SALES NETWORK IN THE AMERICAS USA Carlo Gavazzi Inc. 750 Hastings Lane, Buffalo Grove, IL 60089, USA Tel: +1 847 465 6100 Fax: +1 847 465 7373 sales@carlogavazzi.com MEXICO Carlo Gavazzi Mexico S.A. de C.V. Calle La Montana no. 28, Fracc. Los Pastores Naucalpan de Juarez, EDOMEX CP 53340 Tel & Fax: +52.55.5373.7042 mexicosales@carlogavazzi.com BRAZIL Carlo Gavazzi Automagao Ltda.Av. Francisco Matarazzo, 1752 Conj...

Open the catalog to page 6

All CARLO GAVAZZI catalogs and technical brochures

  1. BSQ-PIR360

    2 Pages

  2. ECH40075

    2 Pages

  3. DCT86A12300

    3 Pages

  4. CGESHTWVT04

    2 Pages