CCW-5113

Mechanical/EquipmentRoom System

DESCRIPTION TOP COAT COLORS

CCW-5113 is a tough, resilient waterproofi ng system consisting of a one-part polyurethane Base Coat and a one-part aliphatic polyurethane Top Coat. The system prevents water from entering occupied space below, protects the surface to which it is applied from damage by water and salts and provides a safe, slip-resistant, attractive walking surface. The Top Coat is available in many fade- resistant colors. Standard colors in stock include Stone Gray, Colonial Gray, Beige, Desert Tan and Arizona Tan.Additional standard colors and custom colors are available, minimum orders may apply.

CCW-501 BASE COAT CCW-503 TOP COAT WARNINGS AND HAZARDS

PROPERTYMETHODTYPICAL VALUE

TYPICAL USE

Solids ContentASTM C125085%Hardness, Shore AASTM D224063 Tensile StrengthASTM D412850 psi Tear, Die CASTM D412625% Recoat Time*ASTM D624140 lb/in Adhesion to ConcreteASTM D90323 PLILow Temp FlexibilityASTM D522-65F The CCW-5113 System is especially designed for waterproofi ng concrete decks in mechanical equipment rooms. For interior areas in occupied buildings where solvent vapors may be a problem, use the Eco-Fast 100%-Solids Pedestrian/Mechanical Room System.

LIMITATIONS

Do not apply primer or coatings to a frosty, damp or wet surface. Do not proceed with coating application if temperature is below 40F or if rain is imminent within 8 hours after application. Cure time is slower in cool weather. Polyurethane coating cure times may be signifi cantly faster than listed when temperature and/or humidity are high. Do not apply in areas where the coating will be exposed to temperatures above 200F. If metal pan is used for concrete form, the pan must be vented. Not for use on grade. If deck has a between-slab membrane, consult with Carlisle representative.

PROPERTYMETHODTYPICAL VALUE

Solids ContentASTM C125072%Hardness, Shore AASTM D224091 Tensile StrengthASTM D4123200 psi Tear, Die CASTM D412190% Recoat Time*ASTM D624300 lb/in Low Temp Flexibility and crack bridging**ASTM C957PassWeather ResistanceASTM G53No chalking@ 2000 hrsAbrasionResistance**ASTM C501<50 mgPermeability**ASTM E96 (B)<1.0 perms

PACKAGING

CCW-501 Base Coat and CCW-503 Top Coat: 5-gallon pails and 55-gallon drums.CCW-501-T Detail Coat:5-gallon pailsShelf life 12 months from date of manufacture when stored at 85F or below.
* Individual lots may vary +/- 10% from Typical value ** System Before use, refer to MSDS for important warnings and safety information. Use only in areas with adequate ventilation. Avoid breathing vapors. Keep away from heat and fl ame. Avoid contact with eyes and skin. In the event of skin contact, remove immediately and wash with warm, soapy water. Wear eye protection. Always wash hands before eating.

APPLICABLE STANDARDS

ASTM E84 Class IIASTM C957-93