video corpo
cad

Renewable Energy
1 /64Pages

Renewable Energy

Renewable Energy
1 /64Pages

Catalog excerpts

Renewable Energy-1

Carling Technologies* Innovative Designs. Powerful Solutions.

 Open the catalog to page 1
Renewable Energy-2

Since its founding, Carling forged a tradition of leadership in quality and product innovation. There are few products that Carling Technologies hasn't turned "ON" and fewer industries that haven't turned to Carling for solutions. With ISO and TS registered Hj manufacturing facilities and technical sales offices worldwide, Carling ranks among the world's largest manufacturers of circuit breakers, switches, power distribution units, digital switching systems and electronic controls. • GFCI / ELCI • Control Modules POWER SYSTEMS • Programmable Displays • Data Communication Interfaces • Electrical...

 Open the catalog to page 2
Renewable Energy-3

Renewable Energy Circuit Breakers & Disconnects When you integrate Carling Technologies circuit breakers into your renewable energy generating systems, you are guaranteed maximum protection against harmful overcurrent. Further, Carling’s circuit breakers utilize the hydraulic/magnetic principal offering many advantages over other thermal magnetic circuit breakers and fuses currently available. In other words, using Carling Technologies circuit breakers protects not only the power system itself, but it also safeguards the structure where these systems are installed by eliminating the fire hazard...

 Open the catalog to page 3
Renewable Energy-4

Product Selector Guide CIRCUIT PROTECTION 1-2, + auxiliary switch pole 1-6 (handle) 1-3 (rocker & metal toggle) Actuator Style sealed metal toggle handle rocker Available Delays DC: instant, ultrashort, short, medium & long AC, DC, AC/DC: instant, ultrashort, short, medium & long AC, DC: high inrush-short, medium & long AC, DC, AC/DC: instant, short, medium & long AC, DC, AC/DC: high inrushshort, medium & long AC, DC: short, medium & long Max Current & Voltage Ratings UL Listed and UL Recognized up to 10,000 amps listed construction fuse backup with fuse backup Available Circuits series trip...

 Open the catalog to page 4
Renewable Energy-5

CX-Series CX-Series Circuit Breaker - Introduction CIRCUIT BREAKER The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent magnets located at the entrance of the arc chamber combined with the upper and lower arc runner...

 Open the catalog to page 5
Renewable Energy-6

CX-Series Circuit Breaker - Design Features DESIGN FEATURES HYDRAULIC/MAGNETIC SENSING COIL UPPER ARC RUNNER Aids in motivating arc off of movable contact and into arc chamber PATENT PENDING MAGNETIC FLUX BOOSTING TERMINAL CONFIGURATION Design enhances motivation of arc into arc chamber LOWER ARC RUNNER Aids in motivating arc off of stationary contact and into arc chamber ARC SPLITTER RETAINER with integrated pressurizing walls LARGE ARC GAP To generate high arc voltages (12) ARC DEIONIZING SPLITTER PLATES

 Open the catalog to page 6
Renewable Energy-7

CX-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Listed (UL489) configuration and performance capabilities as a Molded Case Circuit Breaker CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION MAX CURRENT INTERRUPTING NUMBER RATING AMPS CAPACITY (AMPS) OF POLES Table B: Lists UL Recognized configurations and performance capabilities as a Component Supplementary Protector CX SERIES TABLE B : UL1077 COMPONENT SUPPLEMENTARY PROTECTOR VOLTAGE CIRCUIT CONFIGURATION MAX INTERRUPTING CURRENT CAPACITY (AMPS) FREQUENCY RATING AMPS...

 Open the catalog to page 7
Renewable Energy-8

CX-Series Circuit Breaker - General Specifications Maximum Voltage Overload 600 VDC 50 operations at 600% of rated current for UL489, and at 150% of rated current for UL1077. RESISTANCE PER POLE VALUES RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals from Line to Load Terminals (Values Based on (Values Based on Series Trip Circuit Breaker) Trip Circuit Breaker) Current (amps) CURRENT 0.1(AMPS) -5.0 AMPERE RATING Number of Poles Termination Terminals Termination Barrier Mounting Actuator Internal Circuit Config. Materials Weight Standard Color 1- 2 poles, + Auxiliary Switch Pole. 10-32...

 Open the catalog to page 8
Renewable Energy-9

CX-Series Circuit Breaker - UL489 – Ordering Scheme 9 Actuator Color & Legend 1 SERIES C 2 ACTUATOR X Handle, one per pole 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White A B Black C D Red F G Green H J Blue K L Yellow M N Gray P Q Orange R S 3 POLES 1 One 2 Two 4 CIRCUIT B Series Trip (current) 5 AUXILIARY/ALARM SWITCH 0 Without Aux Switch Dual Legend Color 1 Black 2 White 3 White 4 White 5 White 6 Black 7 Black 8 Black 10 MOUNTING INSERTS A 6-32 Thread B M3 Thread 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 7 CURRENT RATING (AMPERES) CODE 12 AGENCY APPROVAL...

 Open the catalog to page 9
Renewable Energy-10

CX-Series Circuit Breaker - UL489B – Ordering Scheme 1 SERIES C 2 ACTUATOR X Handle, one per pole 3 POLES 1,2 2 Two 3 Three 4 Four 5 Five 4 CIRCUIT S Switch Only 5 RELAY TRIP VOLTAGE COIL RATING 1,2 0 Without Relay Trip Voltage Coil A 12 VDC B 24 VDC C 32 VDC D 48 VDC 6 FREQUENCY & DELAY 03 DC Switch Only 7 CURRENT RATING (AMPERES) 1,3 2-Pole Section 810 50A - 100A 4-Pole Section 917 110A - 175A 9 Actuator Color & Legend 8 TERMINAL 4,5 3 Stud, 1/4-20 6 Stud, M6 A Stud, 1/4-20, with 10-32 Screw Terminals on Voltage Pole B Stud, M6, with M5 Screw Terminals on Voltage Pole 9 HANDLE COLOR & LEGEND...

 Open the catalog to page 10
Renewable Energy-11

CX-Series Circuit Breaker - UL1077 – Ordering Scheme 2 ACTUATOR X Handle, one per pole 4 CIRCUIT Switch Only (no coil) 1, 9 A B Series Trip (current) Relay Trip (voltage) 1, 2, 3, 9 G Dual Legend Color 1 Black 2 White 3 White 4 White 5 White 6 Black 7 Black 8 Black 11 MAX. APPLICATION RATING 10 300VDC 11 440 VDC without factory installed terminal bus 4 14 440VDC with factory installed terminal bus 4 06 600VDC 5 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 12 AGENCY APPROVAL A Without Approvals C UL 1077 Recognized W UL...

 Open the catalog to page 11

All Carling Technologies catalogs and technical brochures

  1. 641-Series

    6  Pages

  2. Military Catalog

    174  Pages

  3. Marine Catalog

    190  Pages

  4. H-Series

    14  Pages

  5. Carling GFCI

    29  Pages

  6. VP-Series

    6  Pages

  7. W-Series

    10  Pages

  8. R135-Series

    2  Pages

  9. V-Series-Rotary

    10  Pages

  10. ST-Series

    8  Pages

  11. C-Series

    4  Pages

  12. D-Series

    4  Pages

  13. DK-EK-Series

    4  Pages

  14. F-Series

    4  Pages

  15. G-Series

    4  Pages

  16. H-I-Series

    4  Pages

  17. LT-Series

    4  Pages

  18. BD-Series

    10  Pages

  19. TB-Series

    6  Pages

  20. PB-Series

    12  Pages

  21. PC-Series

    14  Pages

  22. V-Charger

    6  Pages

  23. ROCKER SWITCHES

    176  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.