Carling Technologies* Innovative Designs. Powerful Solutions. GFCI /ELCI Circuit Protection
Open the catalog to page 1Since its founding, Carling Technologies has continually forged a tradition of leadership in quality and product innovation. There are few products that Carling Technologies hasn’t turned “ON” and fewer industries that haven’t turned to Carling for solutions. With ISO and TS registered manufacturing facilities and technical sales offices worldwide, Carling ranks among the world’s largest manufacturers of circuit breakers, switches, power distribution units, digital switching systems and electronic controls. SWITCHES & CONTROLS • Rocker • Toggle • Pushbutton • Rotary CIRCUIT PROTECTION • Hydraulic-Magnetic •...
Open the catalog to page 2GFCI/ELCI Circuit Protection This catalog features Carling Technologies’ current line of GFCIs/ELCIs products, which offer maximum equipment protection against overload and short circuits. Carling’s Equipment leakage circuit breakers function as hydraulic-magnetic circuit breakers, offering customized overload and short circuit protection. In addition, they sense and guard against faults to ground using innovative electronics technologies. With the exception of small amounts of leakage, the current returning to the power supply will be equal to the current leaving the power supply. If the difference...
Open the catalog to page 3*Manufacturer reserves the right to change product information without prior notice
Open the catalog to page 4PB-Series - Introduction The new PB-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. It utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. These precision mechanisms are temperature stable and are not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature...
Open the catalog to page 5PB-Series Circuit Breaker - General Specifications Electrical Tables Mechanical Table A: UL Listed configurations and performance capabilities as Circuit Breakers. Moisture Resistance Salt Spray Thermal Shock Operating Temperature Corrosion Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Ultrashort curves tested @ 90% of rated current. Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Method 106D, i.e., ten 24-hour...
Open the catalog to page 6PB-Series Circuit Breaker - Ordering Scheme Circuit Actuator Terminal Actuator Mounting/ Color Barriers 10 11 Trip Level Agency Approval 2 SYSTEM VOLTAGE / POLES A 120 VAC single phase, one pole B 120/240 VAC single phase, two pole C 120/240 VAC single phase with switched neutral, three pole D 120 VAC two pole with switched neutral 4 ACTUATOR 1 Handle A one per pole B one per multipole unit Two Color Curved Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single Color Curved Rocker J...
Open the catalog to page 7PB-Series Circuit Breaker - Dimensional Specifications LINE TERM INDICATE "OFF" AND SINGLE COLOR 1-POLE 120 VAC VERSION 2-POLE 120/240 VAC WITH NEUTRAL BREAK TERMINAL DIMENSIONAL DETAIL & RATING TABLE A TIGHTENING TORQUE SPECIFICATIONS Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified.
Open the catalog to page 8PB-Series Circuit Breaker - Dimensional Specifications TYPICAL 2-POLE 120/240 VAC WITH NEUTRAL BREAK VERSION Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified.
Open the catalog to page 9PB-Series Circuit Breaker - Wiring Diagrams 120 VAC with Switched Neutral 120 VAC without Switched Neutral SYSTEM NEUTRAL SYSTEM NEUTRAL GFCI MODULE PIGTAIL GFCI MODULE PIGTAIL LOAD HOT LOAD NEUTRAL LINE/SYSTEM NEUTRAL 120 VAC WITH SWITCHED NEUTRAL 120 VAC WITHOUT SWITCHED NEUTRAL 120 VAC WITH SWITCHED NEUTRAL 120 VAC WITHOUT SWITCHED NEUTRAL 120/240 VAC with Switched Neutral 120/240 VAC without Switched Neutral SYSTEM NEUTRAL SYSTEM NEUTRAL GFCI MODULE PIGTAIL GFCI MODULE PIGTAIL LOAD NEUTRAL LINE/SYSTEM NEUTRAL 120 VAC WITH SWITCHED NEUTRAL 120/240 VAC WITH SWITCHED NEUTRAL 120 VAC WITHOUT...
Open the catalog to page 10PB-Series Circuit Breaker - Panel Seal Ordering Scheme Type Series Actuator Poles Mounting 1 TYPE NUMBER 8 Circuit Breaker Assembly 3 ACTUATOR TYPE 1 Handle, one per pole 2 Handle, one per multipole unit 5 MOUNTING SCREWS / PLATE MATERIAL 1 1 6-32 Thread Phillips Head 2 M-3 Thread Phillips Head 3 6-32 Thread Slotted Head 4 M-3 Thread Slotted Head 5 6-32 Thread Phillips Head with Stainless Steel Plate 6 M-3 Thread Phillips Head with Stainless Steel Plate 7 6-32 Thread Slotted Head with Stainless Steel Plate 8 M-3 Thread Slotted Head with...
Open the catalog to page 11PB-Series Circuit Breaker - Panel Seal Configuration - Dimensional Specifications HANDLE, 1 PER MULTIPOLE UNIT
Open the catalog to page 12PB-Series Circuit Breaker - Time Delay Curves Short Long www.carlingtech.com
Open the catalog to page 13PC-Series Circuit Breaker - Introduction The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. It detects lower level ground faults that do not trip ordinary circuit breakers, but could lead to shock hazards and fires in installations near water. Innovative features include status LED indicators distinguishing if a breaker is closed with line voltage present, or has opened due to leakage current, or has opened due to over current,...
Open the catalog to page 14PC-Series Circuit Breaker - Design Features PC-Series Switch DESIGN FEATURES MOUNTING PLATE Available in stainless steal or zinc chromate plated carbon steel OPTIONAL SEAL IP66/67 panel seals provide ideal protection against salt spray, ozone, dust, water and most acids Two separate lights that indicate power, ground fault leakage and end-of-life
Open the catalog to page 1514 Pages
6 Pages
174 Pages
190 Pages
8 Pages
14 Pages
10 Pages
12 Pages
202 Pages
26 Pages
20 Pages
28 Pages
4 Pages
4 Pages
14 Pages
14 Pages
6 Pages
10 Pages
4 Pages
2 Pages
10 Pages
4 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
10 Pages
20 Pages
6 Pages
12 Pages
14 Pages
6 Pages
176 Pages
114 Pages
4 Pages
64 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
172 Pages
84 Pages
18 Pages
28 Pages