catalogue search
|
You may also be interested in
Parallel gripper, Venturi ejector, Quick coupling, Short stroke cylinder, Guide
Text version of the page
The company reserves the right to vary models and dimensions without notice.
Products designed for industrial applications. Sale to general public is forbidden. CONTROL
CONTROL > Valve Island Series H CATALOGUE > Release 8.1
12
2
2/3.15
New
New
The principal features are: electrical connections on the same
side as the pneumatic connections, Bus-In Bus –out system for
connection to the Fieldbus network, double electrical supplies,
one for control and the other for power, CamiNet outlet to
transfer signals to the Expansion modules, with a possibility
of connecting a maximum of 15 Expansion modules up to
a maximum distance of 50 m. All the internal connections
are on circuit boards with plug-in connectors to make future
modifications easier to achieve. The Initial module electronics
are capable of handling 64 inputs and 64 outputs. The outputs
are on the right hand side of the unit and the inputs on the
left hand side. The 64 output units allow connection of up to
32 positions for monostable or bistable valves. Custom Made
versions enable up to 60 monostable valves (10,5mm only).
Any outputs not used on the IM (initial module) are transferred
for use by the expansion units.
Different types of elements are available for Outputs, the
features of these elements determine the maximum number
that can be used. The addressing and configuration is done
through rotary switches located under the cover and the
LEDs indicate the working state. Expansion modules are
only capable of handling Outputs, up to the maximum number
allowed for each IM (taken into account the number of outputs
used by the IM). Connections between each of the modules are
done by using cables (5 core) in various pre-cut lengths with
M9 connectors. The use of expansion modules linked via the
CamiNet line proves more economical as it does not require a
supply and Fieldbus connection, also enabling the use of less
powerful controllers.
The principal features are: electrical connections on the same
side as the pneumatic connections, Bus-In Bus –out system for
connection to the Fieldbus network, double electrical supplies,
one for control and the other for power.
All the internal connections are on circuit boards with plug-in
connectors to make future modifications easier to achieve.
This version is capable of handling 64 inputs and 64 outputs.
The outputs are on the right hand side of the unit and the
inputs on the left hand side.
The 64 output units allow connection of up to 32 positions for
monostable or bistable valves. Custom Made versions enable
up to 60 monostable valves (10,5mm only).
Each island represents a node in the field bus network and as
it does not have any local Fieldbus outlet it is particularly suited
to a single applications or applications with a limited number of
Valve islands.
This feature enables economic solutions, as there is a large
choice of various Input and Output modules available, which
are the same as the Expansion versions.
Both this version and the Initial Module plus expansion version
can be equipped with Solenoid valves in size 1 (10,5mm) and
size 2 (21mm), or a mixture of both sizes.
Multiple pressure zones and separate electrical supplies are
available using intermediate plates.
With mixed islands pneumatic and electrical adaptor plates are
not necessary and the number of valve positions will not be
reduced as the addressing is done via rotary switches, with the
LEDs indicating the working state.
Example of Expandable Fieldbus System with both Initial and Expansion Modules
Example with Individual Fieldbus Modules.
|