BS700 Series Professional Auto Range TRMS DMM with RS232 - Caltek Industrial - #19 |
|
You may also be interested in
Recorder, Tester, Multimeter, Thermo hygrometer, Digital thermometer
Text version of the page
BS700 Series ver1.0/MAR.10
Due to our policy of continual product development we reserve the right to amend the specifications of all mentioned products without notice.
BS700 Series_PF_v01
Created on 3/31/2010
Prepared by Kit Page 19 of 21
500ìA 10nA
5mA 100nA
50mA 1ìA
500mA 10ìA
±(0.3% Read. + 5dgt)
±(0.8% Read. +
10dgt)
5A 100ìA ±(0.4% Read. +10dgt)
10A 1mA ±(0.4% Read. +20dgt)
Unspecified
(AC+DC) Voltage and (AC+DC) Current
Functio Accuracy
n Range Resolution
40Hz – 1kHz 1kHz – 10 kHz
DC mV 500mV 100ìV
±(0.5% Read. +
5dgt)
±(0.8% Read. +
5dgt)
5V 1mV
50V 10mV
500V 100mA
±(0.5% Read. +
3dgt)
±(0.8% Read. +
DC V 3dgt)
1000V 1V ±(0.8% Read. + 5dgt)
500ìA 100nA
DC ìA
5mA 1ìA
50mA 10ìA
DC mA
500mA 100ìA
±(0.5% Read. +
3dgt)
±(1.0% Read. +
5dgt)
5A 1mA
DC A
10A 10mA
±(0.8% Read. +
10dgt)
Unspecified
Resistance Measurement
Range Resolution Accuracy Open Circuit
Voltage
50 ƒÇ 0.001ƒÇ ±(0.5% Read. + 20dgt) *
500 ƒÇ 0.01ƒÇ ±(0.1% Read. + 5dgt) *
5 kĂ 0.1Ă
50 kĂ Ă
500 kĂ 10Ă
±(0.1% Read. + 2dgt)
5 MƒÇ 100ƒÇ ±(0.3% Read. + 5dgt)
50 MƒÇ 1kƒÇ ±(0.5% Read. + 20dgt)
< 1.3 V DC
* Using Relative () mode
Conductance (5.000 counts only)
Range Resolution Accuracy
50nS 0.01nS 0.1% + 10
Diode Test
Range Accuracy Test Current
(Typical)
Open circuit
voltage
4.0V 2 %+1 1mA <3.0 V DC
|
|