Self-Priming Liquid Ring Pumps - Calpeda - #1

/ 3


catalogue search
Self-Priming Liquid Ring Pumps - Calpeda
P. 01
Self-Priming Liquid Ring Pumps - Calpeda
P. 02
Self-Priming Liquid Ring Pumps - Calpeda
P. 03
Pages:
Self-Priming Liquid Ring Pumps - Calpeda


See other catalogues for Calpeda

Text version of the page
CA
calpeda
Self-Priming Liquid Ring Pumps
Construction
Close-coupled self-priming liquid ring pumps with star impeller.
Applications
For clean liquids without abrasives, without suspended solids, non-explosive, non-aggressive for the pump materials. If the liquid to be pumped has entrained air or gas or the flow in the suction pipe is not stable. For drawing water out of a well.
For increasing network pressure (follow local specifications).
Operating conditions
Liquid temperature from -10 °C to +90 °C. Ambient temperature up to 40 °C. Negative suction pressure up to 9 m. Continuous duty.
Motor
2-pole induction motor, 50 Hz (n = 2900 rpm). CA: three-phase 230/400 V ± 10%. CAM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box. Insulation class F. Protection IP 54.
Constructed in accordance with IEC 60034.
Special features on request
- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Protection IP 55.
- Special mechanical seal
- Higher or lower liquid or ambient temperatures.
Materials
Components
CA
B-CA
Pump casing Lantern bracket
Cast iron GJL200 EN 1561
Bronze G-Cu Sn 10 EN 1982
Impeller
Brass P- Cu Zn Pb 2 UNI 5705
Shaft
Chrome steel 1.4104 EN 10088 AISI 430
Cr-Ni-Mo steel 1.4401 EN 10088 AISI 316
Mechanical seal
Carbon - Ceramic - NBR
21

pageCatalog pdf di En 2012-02-07-15