Thermosight Series - Calex Electronics - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for Calex Electronics

Text version of the page
Calex Electronics Limited PO Box 2, Leighton Buzzard, Bedfordshire, E ngland LU7 4AZ Tel: +44 (0)1525 373178/853800 F ax: +44 (0)1525 851319 Lo-call Tel: 0845 3108053 E-mail: info@calex.co.uk Online: http://www.calex.co.uk Issue E - Jan 10 Specifications subject to change without notice General Speci fic atio ns Technical Data Thermosight 800 Thermosight 900 and 900 plus Thermosight GL and GL plus Thermosight HT Temperature range -32°C to 800°C -32°C to 900°C 150°C to 1800°C 250°C to 1800°C Spectral range 8 to 14 ìm 8 to 14 ìm 5.14 ìm 1.45 to 1.8 ìm Distance:Spot size ratio 50:1 50:1 50:1 200:1 Close focus lens N/A Option Option Option Accuracy @ 23°C ambient,1.0 emissivity 2% of measured value or 2°C, whichever is greater. 2°C below -10°C 2% of measured value or 2°C, whichever is greater. 2°C below -10°C 2% of measured value or 2°C, whichever is greater. 2°C below -10°C 0.6% of measured value Repeatability 1% of measured value or 1°C, whichever is greater. 2°C below -10°C 1% of measured value or 1°C, whichever is greater. 2°C below -10°C 1% of measured value or 1°C, whichever is greater. 2°C below -10°C 0.2% of measured value Temperature drift 0.03%/°C (23°C) 0.03%/°C (23°C) 0.03%/°C (23°C) 0.01%/°C (23°C) Response time t90 150 ms 150 ms 150 ms 20 ms Emissivity 0.2 to 1.0 0.2 to 1.0 0.2 to 1.0 0.1 to 1.0 Display resolution 0.1°C 0.1°C 0.1°C 0.1°C from 250°C to 999.9°C, 1°C from 1000°C to 1800°C Readings Instantaneous, MAX, MIN or A VG Instantaneous, MAX, MIN or A VG Instantaneous, MAX, MIN or A VG Instantaneous, MAX, MIN, A VG or DIF Data logging 20 points N/A (900) 250 points (900 plus) N/A (GL) 250 points (GL plus) 750 points Serial interface N/A RS232 RS232 USB 2.0 Analogue output N/A N/A (900) 1 mV/°C (900 plus) N/A (GL) 1 mV/°C (GL plus) N/A Acoustic alarm HI/LO HI (900), HI/LO (900 plus) HI HI Units of measurement °C or °F °C or °F °C or °F °C or °F Operating temperature 0°C to 55°C 0°C to 55°C 0°C to 55°C 0°C to 60°C Storage temperature -20°C to 70°C -20°C to 70°C -20°C to 70°C -20°C to 70°C Weight 340 g 340 g 340 g 340 g Environmental protection IP20 IP20 IP20 IP20 THER MOSIGHT 800/900, GL, HT AN D CLOSE F OCUS OPTICAL DIAGRA MS 0 500 1000 2000 81 33 15 24 0.61 0.94 1.30 3.20 DISTANCE: SENSOR TO OBJECT (MM) DISTANCE: SENSOR TO OBJECT (IN) Thermosight 600 SPOT DIA.* (MM) SPOT DIA.* (IN) 0 19.7 39.4 78.7 0 500 1000 2000 220 100 20 60 0.78 2.36 3.93 8.66 DISTANCE: SENSOR TO OBJECT (MM) DISTANCE: SENSOR TO OBJECT (IN) Thermosight 400 SPOT DIA.* (MM) SPOT DIA.* (IN) 0 19.7 39.4 78.7 0 500 1000 2000 140 66 8 37 0.31 1.46 2.60 5.51 DISTANCE: SENSOR TO OBJECT (MM) DISTANCE: SENSOR TO OBJECT (IN) Thermosight 500 SPOT DIA.* (MM) SPOT DIA.* (IN) 0 19.7 39.4 78.7 0 500 1000 2000 60 20 20 20 0.79 0.79 0.79 2.36 DISTANCE: SENSOR TO OBJECT (MM) DISTANCE: SENSOR TO OBJECT (IN) Thermosight 800 and 900 SPOT DIA.* (MM) SPOT DIA.* (IN) 0 19.7 39.4 78.7 0 650 1000 2000 80 20 13 30 0.79 0.51 1.18 3.15 DISTANCE: SENSOR TO OBJECT (MM) DISTANCE: SENSOR TO OBJECT (IN) Thermosight GL SPOT DIA.* (MM) SPOT DIA.* (IN) 0 25.6 39.4 78.7 0 400 800 1500 17.1 11 7.5 4.0 0.43 0.30 0.16 0.67 DISTANCE: SENSOR TO OBJECT (MM) DISTANCE: SENSOR TO OBJECT (IN) Thermosight HT SPOT DIA.* (MM) SPOT DIA.* (IN) 0 15.7 31.5 59.1 0 100 200 300 46 24 2.2 20 0.94 0.09 0.79 1.81 DISTANCE: SENSOR TO OBJECT (MM) DISTANCE: SENSOR TO OBJECT (IN) Thermosight 900 Close Focus SPOT DIA.* (MM) SPOT DIA.* (IN) 0 3.94 7.87 31.5 0 96 200 800 49 28 2.3 20 1.10 0.09 0.79 1.93 DISTANCE: SENSOR TO OBJECT (MM) DISTANCE: SENSOR TO OBJECT (IN) Thermosight GL Close Focus SPOT DIA.* (MM) SPOT DIA.* (IN) 0 3.78 7.87 31.5

pageCatalog pdf di En 2012-05-22-28