Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | The following sensors have a spectral response of 5.14 microns. They are suitable for glass surface measurement in tempering, annealing, forming, sealing, laminating and bending applications. | | | | | | | | | | | | | | | | | | | | | | | | | Dist: Spot | Min Spot Dia. (mm) | Emissivity | Accuracy; Greater of | Output | Construction | | Page | | | | Temperature Range | Convir Model | | | | 100 to 1200 °C | 50:1 | 2.5/6/24 | 0.2 to 1.0 | ± 1 % | 4/20 mA | One Piece | TL-T5-12 | A2-6 | | | | The following sensor has a spectral response of 3.9 microns. It will measure 50 mm to 75 mm into molten glass, making it excellent for average 'gob' temperatures. | | | | 200 to 1000 °C | 33:1 2.5/6/24 | 0.2 to 1.0 ±1 % 4/20 mA | One Piece | TL-T4-10 A2-6 | | | | The following sensors have spectral responses between 1.4 and 3.3 microns and are designed for measuring the temperatures of metals. | | | | 300 to 1300 °C | 100:1 | 6/9/11 | 0.05 to 1.00 | ±0.5 % | 4/20 mA | One Piece | TL-GA-13 | A2-6 | | | | 350 to 1800 °C | 100:1 | 6/9/11 | 0.05 to 1.00 | ±0.5 % | 4/20 mA | One Piece | TL-GA-18 | A2-6 | | | | 50 to 425 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 42-20 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 65 to 425 °C | 50:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 42-30 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 200 to 1375 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 42-40 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 65 to 425 °C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 52-30 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 200 to 1375 °C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 52-40 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 315 to 1150 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 41-20 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 375 to 1500 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 41-30 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 315 to 1150 °C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 51-20 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 375 to 1500 °C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 51-30 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | The following sensors have spectral responses between 0.8 and 1.4 microns and are designed for applications that demand high accuracy and optical resolution under conditions of uncertain or changing emissivity. Application include iron, steel and other metal refining, industrial foundry and processing operations, as well as glass, ceramics, semiconductor, chemical, petrochemical and research. | | | | 650 to 1800 °C | 100:1 | 6/9/11 | 0.05 to 1.00 | ±0.5 % | 4/20 mA | One Piece | TL-S-18 | A2-6 | | | | 800 to 2500 °C | 150:1 | 4/5/7 | 0.05 to 1.00 | ±0.5 % | 4/20 mA | One Piece | TL-S-25 | A2-6 | | | | 650 to 1800 °C | 90:1 | 7 | 0.05 to 1.00 | ± 0.5 % ±1 K | 4/20 mA | Two Piece | OL-3-1 | A2-12 | | | | 550 to 1375 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 41-50 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 650 to 1650 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 41-60 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 750 to 2475 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 41-70 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 550 to 1375 °C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 51-50 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 650 to 1650 °C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 51-60 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | 750 to 2475 °C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 51-70 | A2-13 | | | | | | | | | RS-485 Communications | | | | | | | The following sensors are Dual-wavelength pyrometers. They are designed for measuring the temperatures of bodies where the emissivity is unknown or varying, or the target requires a varying field of view due to chang ing size or distance, also where varying concentrations of dust or smoke or sight-window coating are present. | | | | 150 to 315°C | 17:1 | | | | 4/20 mA or 0/20 mA | One Piece | | A2-15 | | | | 0.25 % to 0.50 % | PRO 82-5 | | | | | | | | | RS-485 Communications | | | | | | | 200 to 475°C | 17:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 82-10 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 260 to 600°C | 25:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 82-25 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 475 to 1475°C | 75:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 82-40 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 375 to 1150°C | 75:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 81-10 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 475 to 1750°C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 81-20 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 550 to 2200°C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 81-30 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 650 to 1100°C | 30:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 81-40 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 750 to 1375°C | 75:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 81-50 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 875 to 1750°C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 81-65 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 925 to 2475°C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 81-70 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 200 to 475°C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 92-10 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 260 to 600°C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 92-25 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 475 to 1475°C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 92-40 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 375 to 1150°C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 91-10 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 475 to 1750°C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 91-20 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 550 to 2200°C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 91-30 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 650 to 1100°C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 91-40 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 750 to 1375°C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 91-50 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 875 to 1750°C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 91-65 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | 925 to 2475°C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 91-70 | A2-15 | | | | | | | | | RS-485 Communications | | | | | | | The following sensors are multi-wavelength pyrometers. They are designed for use with 'non-greybody' materials such as aluminium, brass, chrome, copper, molybdenum, stainless s | teel, tin, titanium, tungsten and zinc. | | | | 150 to 315 °C | 17:1 | | | | 4/20 mA or 0/20 mA | One Piece | | A2-17 | | | | 0.25 % to 0.50 % | PRO 120-5 | | | | | | | | | RS-485 Communications | | | | | | | 200 to 475 °C | 17:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 120-10 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 200 to 600 °C | 17:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 120-20 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 260 to 600 °C | 25:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 120-25 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 475 to 1475 °C | 75:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 120-40 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 375 to 1150 °C | 75:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 110-10 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 475 to 1750 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 110-20 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 550 to 2200 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 110-30 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 650 to 1100 °C | 30:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 110-40 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | A2-17 | 75:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 110-50 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 875 to 1750 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 110-65 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 925 to 2475 °C | 100:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | One Piece | PRO 110-70 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 200 to 475 °C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 220-10 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 260 to 600 °C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 220-25 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 475 to 1475 °C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 220-40 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 375 to 1150 °C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 210-10 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 475 to 1750 °C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 210-20 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 550 to 2200 °C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 210-30 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 650 to 1100 °C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 210-40 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 750 to 1375 °C | 12:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 210-50 | A2-17 | | | | | | | | | RS-485 Communications | | | | | | | 875 to 1750 °C | 16:1 | | | 0.25 % to 0.50 % | 4/20 mA or 0/20 mA | Two Piece | PRO 210-65 | | | |