| | | ♦ Wide temperature range from 150 to 2475°C ♦ Industry leading signal dilution capability ♦ Revolutionary ESP algorithms provide 'aim and read' capability for applications where single and dual wavelength sensors cannot take readings ♦ Views through obstructions like steam, smoke, plasma, dirty optics, dust and most common window materials ♦ Can be used in applications with a partially filled field of view caused by mechanical obstructions and a small or wandering target | | |
| | | GENERAL SPECIFICATIONS PRO 100 SERIES - Visual Aiming, Multi-Wavelength (MX) Sensors | | |
| | | |
| | | | | | | | | | | | | | | PRO | Temperature | Nominal | Field of View | Signal Dilution | | | | Model | Range | Spectral | Standard | High | Temperature | Top | | | | | | Response | or Large | Resolution | Where | End | | | | | | (microns) | Resolution Optics | Optics | Exceeds 20:1 | | | | | 120-5 | 150-315°C | 2 urn | 17:1 | N/A | 190°C | 300:1 | | | | 120-10 | 200-475°C | 2 um | 17:1 | N/A | 240°C | 900:1 | | | | 120-20 | 200-600°C | 2 um | 17:1 | 35:1 | 240°C | 1200:1 | | | | 120-25 | 260-600°C | 2 um | 25:1 or 17:1 | N/A | 275°C | 1200:1 | | | | 120-40 | 475-1475°C | 2 um | 75:1 | 100:1 | 550°C | 900:1 | | | | 110-10 | 375-1150°C | 1.5 um | 75:1 or 17:1 | N/A | 500°C | 6000:1 | | | | 110-20 | 475-1750°C | 1.5 mm | 100:1 or 17:1 | 150:1 | 660°C | 6000:1 | | | | 110-30 | 550-2200°C | 1.5 um | 100:1 or 17:1 | 150:1 | 720°C | 6000:1 | | | | 110-40 | 650-1100°C | 1um | 30:1 or 17:1 | N/A | 720°C | 1800:1 | | | | 110-50 | 750-1375°C | 1 um | 75:1 or 17:1 | N/A | 860°C | 1800:1 | | | | 110-65 | 875-1750°C | 1 um | 100:1 or 25:1 | 150:1 | 1040°C | 1800:1 | | | | 110-70 | 925-2475°C | 1 um | 100:1 or 25:1 | 150:1 | 1300°C | 1800:1 | | | | | | | | | | | | | | |
| | | |
| | | The PRO series 100 and 200 multi-wavelength infrared temperature sensors are designed to accurately measure non-greybody materials in applications where single and dual wavelength sensors cannot. These include aluminium extrusion and molten aluminium streams, iron and steel streams, galvanised and stainless steel production. These sensors industry leading signal dilution factor allows them to measure very small and wandering targets, and tolerate misalignment, dirty lenses and partially filled fields of view, while industrial still giving accurate readings. Their intuitive text based configuration system makes the PRO series simple and quick to programme for even the most demanding application, while advanced ESP algorithms and signal processing ensure that these sensors always provide valid readings, or hold the last valid reading until another can be taken. This further removes errors from poor alignment and transient process conditions that could cause unnecessary errors in other systems. Fibre-optic and traditional industrial camera style versions of the Pro multi-wavelength sensors are available to suit all mounting conditions. Either laser or through lens sighting is available on all models, and all come with bi-directional RS-485 communications for configuration and measurement readings. | | |
| | | |
| | | PRO 200 SERIES - Fibre Optic, Multi-Wavelength (2X) Sensors | | |
| | | |
| | | | | | | | | | | | | | | | | | PRO Model | Temperature Range | Nominal Spectral Response (microns) | Field of View | Fiber Cable | Signal Dilution | | | | Standard Resolution Optics (2) | High Res I. Optics | High Res. II Optics | Max Length | Type of Cable | Temperature Where Exceeds 20:1 | Top End | | | | 220-10 | 200-475°C | 2 um | 2:1 or 12:1 | N/A | 50:1 | 91cm | Quartz | 240°C | 1200:1 | | | | 220-25 | 260-600°C | 2 um | 2:1 or 12:1 | N/A | 50:1 | 91cm | Quartz | 275°C | 1200:1 | | | | 220-40 | 475-1475°C | 2 um | 2:1 or 16:1 | 50:1 | 75:1 | 1.8m | Quartz | 550°C | 900:1 | | | | 210-10 | 375-1150°C | 1.5 um | 2:1 or 12:1 | N/A | 50:1 | 9.1m | Quartz | 500°C | 6000:1 | | | | 210-20 | 475-1750°C | 1.5 um | 2:1 or 16:1 | 50:1 | 75:1 | 9.1m | Quartz | 660°C | 6000:1 | | | | 210-30 | 550-2200°C | 1.5 um | 2:1 or 16:1 | 50:1 | 75:1 | 9.1m | Quartz | 720°C | 6000:1 | | | | 210-40 | 650-1100°C | 1 um | 0.75:1 or 12:1 | N/A | 50:1 | 6.0m | Glass | 720°C | 1800:1 | | | | 210-50 | 750-1375°C | 1 um | 0.75:1 or 12:1 | N/A | 50:1 | 7.6m | Glass | 860°C | 1800:1 | | | | 210-65 | 875-1750°C | 1 um | 0.75:1 or 16:1 | 50:1 | 75:1 | 9.1m | Glass | 1040°C | 1800:1 | | | | 210-70 | 925-2475°C | 1 um | 0.75:1 or 16:1 | 50:1 | 75:1 | 9.1m | Glass | 1300°C | 1800:1 | | | | | | | | | | | | | | | | | |
| | | |
| | | 0.25% to 0.5% of Reading or 2°C (varies by model) Better than 1°C 100ms (update time) 400ms (98% of Reading - 4t) EMI / RFI for heavy industry; LVD (Low Voltage Directive) All Models: -17 to 60°C Except 120-5: -17 to 50°C 50°C 95-175°C (this varies with water rate and temperature) 200°C | | |
| | | Accuracy Repeatability Response Time Constant Target: Intermittent Target: CE Certification Ambient Temperature Limits Sensor Head: Fibre Optic Assembly: | | |
| | | |
| | | Calex Electronics Limited PO Box 2, Leighton Buzzard Bedfordshire, England LU7 4AZ Tel: +44 (0)1525 373178/853800 Fax: +44 (0)1525 851319 Lo-call Tel: 0845 3108053 E-mail: info©calex.co.uk Online: http://www.calex.co.uk | | |
| | | |
| | | A2-17 | | |
| | | Issue A - Feb 03 | | |
| | | Specifications subject to change without notice | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | |