Convir PRO 100 and 200 series Multi-Wavelength Industrial temperature sensors
♦ Wide temperature range from 150 to 2475°C
♦ Industry leading signal dilution capability
♦ Revolutionary ESP algorithms provide 'aim and read' capability for applications where single and dual wavelength sensors cannot take readings
♦ Views through obstructions like steam, smoke, plasma, dirty optics, dust and most common window materials
♦ Can be used in applications with a partially filled field of view caused by mechanical obstructions and a small or wandering target
GENERAL SPECIFICATIONS
PRO 100 SERIES - Visual Aiming, Multi-Wavelength (MX) Sensors
PRO
Temperature
Nominal
Field of View
Signal Dilution
Model
Range
Spectral
Standard
High
Temperature
Top
Response
or Large
Resolution
Where
End
(microns)
Resolution Optics
Optics
Exceeds 20:1
120-5
150-315°C
2 urn
17:1
N/A
190°C
300:1
120-10
200-475°C
2 um
17:1
N/A
240°C
900:1
120-20
200-600°C
2 um
17:1
35:1
240°C
1200:1
120-25
260-600°C
2 um
25:1 or 17:1
N/A
275°C
1200:1
120-40
475-1475°C
2 um
75:1
100:1
550°C
900:1
110-10
375-1150°C
1.5 um
75:1 or 17:1
N/A
500°C
6000:1
110-20
475-1750°C
1.5 mm
100:1 or 17:1
150:1
660°C
6000:1
110-30
550-2200°C
1.5 um
100:1 or 17:1
150:1
720°C
6000:1
110-40
650-1100°C
1um
30:1 or 17:1
N/A
720°C
1800:1
110-50
750-1375°C
1 um
75:1 or 17:1
N/A
860°C
1800:1
110-65
875-1750°C
1 um
100:1 or 25:1
150:1
1040°C
1800:1
110-70
925-2475°C
1 um
100:1 or 25:1
150:1
1300°C
1800:1
The PRO series 100 and 200 multi-wavelength infrared temperature sensors are designed to accurately measure non-greybody materials in applications where single and dual wavelength sensors cannot. These include aluminium extru­sion and molten aluminium streams, iron and steel streams, galvanised and stainless steel pro­duction.
These sensors industry leading signal dilution factor allows them to measure very small and wandering targets, and tolerate misalignment, dirty lenses and partially filled fields of view, while industrial still giving accurate readings.
Their intuitive text based configuration system makes the PRO series simple and quick to pro­gramme for even the most demanding applica­tion, while advanced ESP algorithms and signal processing ensure that these sensors always pro­vide valid readings, or hold the last valid reading until another can be taken. This further removes errors from poor alignment and transient process conditions that could cause unnecessary errors in other systems.
Fibre-optic and traditional industrial camera style versions of the Pro multi-wavelength sensors are avail­able to suit all mounting conditions. Either laser or through lens sighting is available on all mod­els, and all come with bi-directional RS-485 com­munications for configuration and measurement readings.
PRO 200 SERIES - Fibre Optic, Multi-Wavelength (2X) Sensors
PRO
Model
Temperature Range
Nominal Spectral Response (microns)
Field of View
Fiber Cable
Signal Dilution
Standard Resolution
Optics (2)
High Res I. Optics
High Res. II Optics
Max Length
Type
of
Cable
Temperature
Where
Exceeds
20:1
Top
End
220-10
200-475°C
2 um
2:1 or 12:1
N/A
50:1
91cm
Quartz
240°C
1200:1
220-25
260-600°C
2 um
2:1 or 12:1
N/A
50:1
91cm
Quartz
275°C
1200:1
220-40
475-1475°C
2 um
2:1 or 16:1
50:1
75:1
1.8m
Quartz
550°C
900:1
210-10
375-1150°C
1.5 um
2:1 or 12:1
N/A
50:1
9.1m
Quartz
500°C
6000:1
210-20
475-1750°C
1.5 um
2:1 or 16:1
50:1
75:1
9.1m
Quartz
660°C
6000:1
210-30
550-2200°C
1.5 um
2:1 or 16:1
50:1
75:1
9.1m
Quartz
720°C
6000:1
210-40
650-1100°C
1 um
0.75:1 or 12:1
N/A
50:1
6.0m
Glass
720°C
1800:1
210-50
750-1375°C
1 um
0.75:1 or 12:1
N/A
50:1
7.6m
Glass
860°C
1800:1
210-65
875-1750°C
1 um
0.75:1 or 16:1
50:1
75:1
9.1m
Glass
1040°C
1800:1
210-70
925-2475°C
1 um
0.75:1 or 16:1
50:1
75:1
9.1m
Glass
1300°C
1800:1
0.25% to 0.5% of Reading or 2°C (varies by model) Better than 1°C
100ms (update time) 400ms (98% of Reading - 4t)
EMI / RFI for heavy industry; LVD (Low Voltage Directive)
All Models: -17 to 60°C Except 120-5: -17 to 50°C
50°C
95-175°C
(this varies with water rate and temperature)
200°C
Accuracy
Repeatability
Response Time Constant Target: Intermittent Target:
CE Certification
Ambient Temperature Limits Sensor Head:
Interface Module: Sensor w/ Water cooling:
Fibre Optic Assembly:
Calex Electronics Limited
PO Box 2, Leighton Buzzard Bedfordshire, England LU7 4AZ Tel: +44 (0)1525 373178/853800 Fax: +44 (0)1525 851319 Lo-call Tel: 0845 3108053 E-mail: info©calex.co.uk Online: http://www.calex.co.uk
A2-17
Issue A - Feb 03
Specifications subject to change without notice
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
pdf-page pdf di En 2008-11-47-23