THERMOSIGHT EQUIPMENT TABLE
Thermosight
Thermosight
Thermosight
Thermosight
Thermosight
Thermosight
Thermosight
Thermosight
800
900
GL
HT
900 Plus
GL Plus
900 Plus Set
GL Plus Set
MAX, MIN, AVG, DIF, HOLD
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
RS 232-interface, 9600 Baud
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Data storage
20 values
-
-
750 values
250 values
250 val ues
250 values
250 values
Adjustable storage interval
Yes
-
-
Yes
Yes
Yes
Yes
Yes
Acoustic HI-alarm funct., adjustable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Acoustic LO-alarm funct., adjustable
Yes
-
-
-
Yes
-
Yes
-
Analogue output 1 mV/°C
-
-
-
Yes
Yes
Yes
Yes
Yes
Connection for a recharger
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Certificate of calibration
-
-
-
-
-
-
Yes
Yes
Software
-
Accessories
Accessories
Accessories
Accessories
Accessories
incl.
incl.
RS 232-cable
-
Accessories
Accessories
Accessories
Accessories
Accessories
incl.
incl.
Analogue cable
-
Accessories
Accessories
Accessories
Accessories
Accessories
incl.
incl.
Thermometer with probe
Accessories
Accessories
Accessories
Accessories
Accessories
Accessories
incl.
incl.
Close-focus lens
-
Accessories
Accessories
-
Accessories
Accessories
Accessories
Accessories
Holster
Accessories
Accessories
Accessories
Accessories
Accessories
Accessories
Accessories
Accessories
" YeS' : with the instrument. "incl.": inclusive. not with the instrument
THERMOSIGHT 800/900, GL, HT AND CLOSE FOCUS OPTICAL DIAGRAMS
Thermosight 800 and 900 Thermosight GL
Thermosight HT
DISTANCE: SENSOR TO OBJECT (IN)
DISTANCE: SENSOR TO OBJECT (IN)
DISTANCE: SENSOR TO OBJECT (IN)
§. 0' 1-.7 3. .4 78.71
<
° 2.361 10.7- 0.7-j 0.7-1
S 0' 25.6 3- .4 78.7'
<
O
a 3.151
J07- 0.51 J
§. 0' 15.7 31.5 5- .1'
<
O
(J) 1.281 0.43J 0.30J 0.16 j ^___T
120 2C)t 20! ——j
<
° 0 , 500 1000, 2000i
_ t20 13^ 30t .
t 80i
<
° 0 , 650 1000 2000,
_ 11 f 7.5Î 4.0Î ' Ï | 32.51
<
° 0 1 400, 800 1 1500 ,
DISTANCE: SENSOR TO OBJECT (MM)
DISTANCE: SENSOR TO OBJECT (MM)
DISTANCE: SENSOR TO OBJECT (MM)
Thermosight 900 Close Focus
Thermosight GL Close Focus
) DISTANCE: SENSOR TO OBJECT (IN)
) DISTANCE: SENSOR TO OBJECT (IN)
2 0'3.- 4 7.87 31.5'
<
O
* 0.0-1 1.811
0.7- J J0.- 4| ^^___J;___—-■
J 0'3.78 7.87 31.51
<
O
* 0.0-1 1.- 31 0.7-J J1.10| T
' 1 24! I ——
5 2.2 461
<
° 0,100, 2001 800 ,
2C)t | 28J 1 -—
5 2.3 4- |
<
° 0, - 6, 200 800,
DISTANCE SENSOR TO OBJECT (MM)
DISTANCE: SENSOR TO OBJECT (MM)
Calex Electronics Limited Tel: +44 (0)1525 373178/853800 Fax: +44 (0)1525 851319 Online: http://www.calex.co.uk
7
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
pdf-page pdf di En 2008-10-41-12