| | | Convel 90000 Chassis Mounting These high quality linear regulated power supplies provide outstanding value and are designed for ease of application and long trouble free life. ♦ Universal AC input 100 - 240VAC ♦ 3.75kV Isolation safety transformer ♦ Short circuit and overload protection ♦ Quality UK design and manufacture | | |
| | | H IVI* W UE | | |
| | | |
| | | ■—I w\ ■ " | | |
| | | |
| | | GENERAL SPECIFICATIONS A.C. Input Line Regulation Load Regulation Output Ripple Short Circuit and Overload Protection Temperature Rating | | |
| | | 100/120/220/240VAC +10%, -12%, 47 to 440Hz ±2.0% for a 10% line change. ±2.0% for a 100% load change. 0.2% PK-PK maximum Automatic current limit/foldback 0°C to +40°C full-rated, derated linearly to 40% at 60°C | | |
| | | |
| | | |
| | | TEMPERATURE DERATING CURVE Convection Cooled\ \Forced1^^ling | | |
| | | | |
| | 100 ■S 80 3 60 I 40 as 20 | | |
| | | |
| | | 10 20 30 40 50 60 Degrees Celcius | | |
| | | |
| | | Efficiency (typical) Isolation | | |
| | | 60% Input to ground: 3750VAC min. Input to output(s): 3750VAC min. Output to ground: 500VAC min. Leakage current (live to ground): 5uA max. In accordance with EN60950 | | |
| | | |
| | | Safety | | |
| | | |
| | | |
| | | | | | | | | | | | Output | Output | | | | Model | Voltage | Current | | | | 91201 | 12V | 1A | | | | 91202 | 12V | 2A | | | | 92401 | 24V | 1.25A | | | | 92402 | 24V | 2A | | | | | | | | | | |
| | | |
| | | MECHANICAL Overall dimensions (l x w x h) Weight Mechanical Format Mounting Orientation | | |
| | | 179 x 118.6 x 88mm 2.3kg All units are supplied fully enclosed as standard Units may be mounted horizontally as shown on the outline drawing overleaf, or vertically with the cables entering from below. Units are convection cooled and therefore require free air flow around the chassis. Units have 4 x M3 ISO standard threaded inserts provided The following industrial connectors are provided on the power supply: Screw terminals are provided for input and output connections Input voltage selection is achieved using links on the transformer | | |
| | | |
| | | Ventilation and Cooling | | |
| | | |
| | | Fixings Connectors | | |
| | | Calex Electronics Limited PO Box 2, Leighton Buzzard Bedfordshire, England LU7 4AZ Tel: +44 (0)1525 373178/853800 Fax: +44 (0)1525 851319 Lo-call Tel: 0845 3108053 E-mail: info©calex.co.uk Online: http://www.calex.co.uk | | |
| | | |
| | | |
| | | C3-11 | | |
| | | Issue B - Oct 04 | | |
| | | Specifications subject to change without notice | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |