VA301C
Gas detection Controller
• Full array of visual indicators and audible alarm
• Multiple fully programmable alarm levels
• Integrated audible alarm
• Programmable time delays
• Failure indicator
• Up to 96 industrial transmitters and relay modules
• Up to 768 events
• No moving parts
• Trouble-free operation
• Quick self-test and warm-up
• Up to 126 zoning groups
• Graphic 122 x 32 Dot Matrix display
• Datalogging capabilities available
• BACnet capability available
VA301C Specifications
Visual Indicators:
Normal Operation:
Green LED
Alarm Level 1:
Red LED
Alarm Level 2:
Red LED
Alarm Level 3:
Red LED
Signal Tx:
Blinking amber LED
Signal Rx:
Blinking green LED
Failure Indication:
Yellow LED
User Interface:
Dot Matrix display and keypad
Network capacity:
Three 32 Modbus zones or
Two 16 Vulbus zones, one 32 Modbus zone
Communication (length off lines):
Up to 2000 feet (600 m)
T-Tap: 65 feet (20 m) max per T-Tap.
130 feet (40 m) max for all T-Tap combined
Relay Output Rating:
5 A, 30 VDC or 250 VAC (resistive load)
Alarm Levels:
Multiple with high and low setpoints
Time Delays:
0, 30 sec., 45 sec., 1-99 minutes before and after alarm
Outputs:
4 DPDT relays (alarms and/or fault), buzzer
Operating Humidity Range:
0-95% RH, non-condensing
Operating Temperature Range:
-4 °F to 122 °F (-20 °C to 50 °C)
General Specifications
Size:
11.02 x 7.99 x 2.76 inches
28 x 20.3 x 7 cm
Weight:
2.4 lbs.(1.1 kg)
Enclosure:
NEMA 4X Polycarbonate - ABS
Power Requirement:
17-27 VAC, 24-38 VDC, 500 mA
Certified to UL and CSA standards
DUE TO ON-GOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Energy Savings
Vulcain's exclusive alarm management capability can result in significant energy savings. Only Vulcain technology can allow for the activation of alarms based on the average of the values read by a group of transmitters, thus considerably reducing energy loss related to fan operation.
Committed to BACnet
In line with its continuous commitment to technological innovation, and in recognition of the benefits of BACnet, Vulcain introduces one of the industry's first advanced BACnet/Ethernet communication module — the VA301BDCM.
BACnef
Division of BW Technologies j 1 800 563-2967 Vulcaininc.com
For further information:
USA
1971 Western Avenue, Unit 1122 Albany, NY USA 12203
Tel: 1-800-563-2967 Fax: 1-888-967-9938
TORONTO
344 Edgeley Boulevard, Unit 13 Vaughan, ON L4K 4B7
Datalogging Capability
Ideal for long-term datalogging to determine trends, the VA301CDS controller or the DLC option for the VA301C collects data automatically and stores it on a digital flash Multimedia Card. Capacity is extraordinary. Store over 3 months of data given a 10 second interval, one transmitter on a 32 MB card.
Tel: Fax:
1-905-660-6544 1-905-660-7362
MONTREAL
4005 Matte Boulevard, Unit G Brossard, QC J4Y 2P4
Locally Distributed by:
Tel:
Fax:
1-800-563-2967 1-888-967-9938
E-mail: sales@vulcaininc.com www.vulcaininc.com
VN1088-01-01-00-8.25x11-20050218-5720-4
I
M M I
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 101 p.101
page 102 p.102
page 103 p.103
page 104 p.104
page 105 p.105
page 106 p.106
page 107 p.107
page 108 p.108
page 109 p.109
page 110 p.110
page 111 p.111
page 112 p.112
page 113 p.113
page 114 p.114
page 115 p.115
page 116 p.116
page 117 p.117
page 118 p.118
page 119 p.119
page 120 p.120
page 121 p.121
page 122 p.122
page 123 p.123
page 124 p.124
page 125 p.125
page 126 p.126
page 127 p.127
page 128 p.128
page 129 p.129
page 130 p.130
page 131 p.131
page 132 p.132
page 133 p.133
page 134 p.134
page 135 p.135
page 136 p.136
page 137 p.137
page 138 p.138
page 139 p.139
page 140 p.140
page 141 p.141
page 142 p.142
page 143 p.143
page 144 p.144
page 145 p.145
page 146 p.146
Pages:
1-50
51-100
101-146
pdf-page pdf di En 2009-01-02-09