8201-5500-N021A 0 ... 500 bar 20.0 8201-5800-N021A 0 ... 800 bar 20.0 8201-6001-N021A 0 ... 1000 bar 20.0 Dimensional drawing model 8201 N

Precision Pressure Transducer - 13615 Technical Data

Order Code Measuring Resonance 8201-5020-N021A 0 ... 20 bar 3.5 8201-5050-N021A 0 ... 50 bar 10.0 8201-5100-N021A 0 ... 100 bar 15.0 8201-5200-N021A 0 ... 200 bar 20.0 8201-5300-N021A 0 ... 300 bar 20.0 Range Frequency [kHz] 8201-5005-N021A 0 ... 5 bar 1.5 8201-5010-N021A 0 ... 10 bar 3.0 Version with measuring ranges ≤ 0 ... 10 bar are 15 mm longer The CAD drawing (3D/2D) for this sensor can be imported online directly into your CAD system. Download via www.burster.com or directly at www.traceparts.com. For further information about the burster traceparts cooperation refer to data sheet 80-CAD-EN. 8201 N EN - 2

Electrical values

Bridge resistance:full bridge circuit of foil strain gauges 350 Ω , nominalCalibration resistor: 100 k Ω

Technical Data

of the Internal Amplifier

The bridge output voltage resulting from a shunt of this value is shown in the test certificate.Excitation voltage: recommended 5 V DC maximum 10 V DCNominal sensitivity: standardized; 1.0 mV/V ± 0.25 % Excitation voltage: 15 ... 30 VPower consumption: voltage output max. 40 mA current output max. 65 mAConnection technology: 3 wireOutput resistance: 200 Ω (15 V) ... 800 Ω (from 24 V)Cut-off frequency: (- 3 dB) 1 kHzRange of operating temperature: 0°C ... 60°C Output resistance: 18 Ω

Environmental conditions

Wiring code: pin A excitation positive pin B ground pin C ground pin D signal output positive pins E + F not connectedDimensions: Transducers with internal amplifier and range ≤ 0 ... 10 bar are 50 mm longer; range Range of operating temperature: - 30 °C ... 120 °C Nominal temperature range: 0 °C ... 70 °C Influence of temp. ≥ 0 ... 20 bar are 15 mm longer measuring range ≤ 0 ... 10 bar ± 0.005 % F.S./Kon zero: measuring range ≥ 0 ... 20 bar ± 0.01 % F.S./K Influence of temp. measuring range ≤ 0 ... 10 bar ± 0.005 % Rdg./Kon sensitivity: measuring range ≥ 0 ... 20 bar ± 0.01 % Rdg./K

Mechanical values

Combined error consisting of non-linearity, hysteresis and variation:

Order Information

High precision pressure transducer, range 0 ... 100 bar,with internal amplifier for 0 ... 5 V 8201-5200-H331A measuring range ≤ 0 ... 10 bar 5.8 cm
3

Accessories

measuring range ≥ 0 ... 20 bar 2.5 cm
3 Thread adaptor, material 1.4571 for following connecting threadsExternal thread M 16 x 1,5 Volume change: negligibly smallOverload: measuring range Model 8281 ≤ 0 ... 300 bar 50 % over capacity External thread G 1/2" A Model 8283 measuring range ≥ 0 ... 500 bar 50 % over capacity External thread R 1/4" (max. 500 bar) Model 8285 Burst pressure: measuring range ≤ 0 ... 500 bar >100 % over capacity measuring range 0 ... 1000 bar > 50 % over capacity Dynamic performance: measuring range Standard sealing ring set (included in scope of delivery) Model 82911 PTFE sealing ring set for critical applications;Teflon-coated Viton
® thrust and O-ring Model 82910 ≤ 0 ... 10 bar recommended 50 % of capacity maximum 70 % of capacity measuring range

Connecting Cables

≥ 0 ... 20 bar recommended 70 % of capacity maximum 100 % of capacityDesign: Diaphragm pressure transducer with hermetically sealed pressure chamber (without internal sealing elements).Material: stainless steel; 1.4548.9 Pressure connection: internal thread M 16 x 1.5 Sealing:Sealing of the transducer is ensured by thrust and O-ring which are parts of delivery. For critical applications a Teflon coated Viton for transducers plug-in connection and bridge output, completely with connector and socket, 6 wire, shielded PVC isolated cable, bending radius > 5 mm, standard length of 3 m.to burster desktop indicators with 12 pin connection Model 9911 to indicator 9162 Model 99545-564C-0100030 with open, color coded and tinned cable ends Model 9986 with open, color coded and tinned cable ends; for transducers with internal amplifier Model 99545-000D-0160030
® O-ring with thrust ring is also available. refer to accessoriesMounting torque: max. 3 NmElectrical connection: 6 pin bayonet connector Souriau 851 07A 10 - 6 PWiring code: pins A + B excitation voltage positive pins C + D excitation voltage negative pins E signal output negative pins F signal output positiveDimensions: refer to dimensional drawing General tolerance for length measurement acc. to ISO 2768-f Weight: approx. 420 g ... 650 g Protection class: acc. to EN 60529 IP65 Mating connector: model 9945 Souriau 851-06E-C-10-6S or Amphenol 62-GB-16F-10-6S in scope of delivery Other cable lengths or customized cables on request.

Option

Option 33 internal amplifier for voltage output 0...5 V Option 37 internal amplifier for current output 0...20 mA Option 39 internal amplifier for current output 4...20 mA Option 41 internal USB interface, resolution up to 16 bit, 2500 measurements per secondOption 42 internal CANopen bus, resolution 16 bit, measuring rate 1 MBaudOption DKD Calibration certificate acc. to standard DKD-R 6-1 for 21 points in 10 %-steps up and down Option WKS WKS manufacturer calibration for 11 points in 20 % steps up and down, each point done twice
286-08201NEN-5072-021511 Technical changes reserved -Latest updates of data sheet always under www.burster.com burster praezisionsmesstechnik gmbh & co kg . Tel. +49-7224-6450 . Fax 64588Talstr. 1-5 . D-76593 Gernsbach . www.burster.com . info@burster.com