24508 E - 2
Digital Megohmmeter - 13615 Technical DataCalibration resistances for the device testingModel series 1270Resistance measurement range: 50 k ... 10 T divided in 8 measurement rangesMeasurement accuracy: 2.5 % of value ±1 digit Current range: 9 pA ... 10 mA divided in 8 measurement rangesMeasurement accuracy: 2.5 % of value ± 1 digit Measurement voltage: 45 V, 100 V, 250 V, 500 V (other voltages upon request)Measurement time: freely selectable up to 999 s Max. current in measurement circuit: 5 mA Measurement range selection: manual or automatic Measurement connections: BNC (red) measurement voltage BNC (black) measurement input 4 mm ø socket (blue) guard 4 mm ø socket (green) groundDisplay: two line LCD display measurement value 3 digits with unitLimit value indicator: potential-free relay output (max. 48 V, 1 A)External measurement start: via potential-free contact Interface: RS232 with 9 pin Sub Min D socket Operating temperature range: 0 °C ... 45 °C Storage temperature: - 20 °C ... + 70 °C Supply voltage: 230 V ± 10 % 50 Hz Device security: acc. to standard EN 61010-1 Power:6 ... 10 8 - 0.02 %/V 10 9 ... 10 12 - 0.04 %/V 10 13 ... 10 14 Construction: metal housing with PVC cover Dimensions: 36 x 30 x 90 [mm] Net weight: approx. 70 g Model Resistance value Accuracy category 1270 10 6 1 % 1271 10 7 1 % 1272 10 8 1 % 1273 10 9 1 % 1274 10 10 1 % 1275 10 11 1 % 1276 10 12 5 % 1277 10 13 5 % 1278 10 14 10 % DKD CalibrationThe calibration resistor model 1270 can be supplied with a DKD certi cate (German calibration service). The documented measurement results and tolerances are captured with standards and measurement instruments that are subject to regular comparison to the national standards of the Federal Rep. of Germany. The veri cation by the appointed state authorities is shown in the certi cate itself as well as the calibration sign which is placed on the device.Order InformationDigital Megohmmeter Model 24508incl. measurement leads 1 m lengthModel 12DKD-1270Accessories WKS CalibrationMeasurement leads 3 m length Model 24508-Z001 The manufacturer test certi cate (WKS) includes the proof of trace-ability for national standards as well as protocolling of measurement results and uncertainties. DKD Calibration Certi cate Model 24DKD-24508 WKS Calibration Certi cate Model 24WKS-24508Model 12WKS-1270Guard ring electrodes for the measurements of surface or volume resistances on requestApplication Guard CircuitThe guard connection is exempliï¬ ed by a guard ring electrode. Depending on the connection wiring the RESISTOMAT® 24508 makes it possible to determinate the surface or volume resistance of the test sample.For the determination of the surface resistance the measuring electrode is connected to the -input, the guard ring is connected with the + input and the basic electrode is connected with the guard input.For the determination of the volume resistance the measuring electrode is connected with the +input, the guard ring with the guard input and the basic electrode is connected with the -input. air gap 123-024508EN-5072-031511 4 Technical changes reserved -Latest updates of data sheet always under www.burster.com burster praezisionsmesstechnik gmbh & co kg . Tel. +49-7224-6450 . Fax 64588Talstr. 1-5 . D-76593 Gernsbach . www.burster.com . info@burster.com |
|