9180 E burster
ex stock/4-6 weeks 24 months
Digital Display for Strain Gauge Units, Potentiometers, DC/DC Sen­sors and Standard Signals
Model 9180
panel-mounted
version
■ For measurements of force, pressure and torque using strain gauge sensors
■ For measurements of positions and angles using Potentiometrie or DC/DC sensors
■ For measurement of temperature using Pt 100 or TC
■ Processing of standard signals ± 1 V/ 5 V/ 10 V/ 0 ... 1 mA, 0 (4) ... 20 mA
■ Min. or max. peak values via an additional display
■ TARE and HOLD functions
■ Configuration of up to 4 setpoint alarms (optional)
■ RS232- or RS485 (optional)
■ Analog or BCD output (optional)
■ Display range - 99999 ... + 99999
■ Accuracy < 0.1 %
■ Scalable through teach-in processes or the entry of sensor data
Desktop version
Application
The model 9180 supports force, pressure and torque sensors operating on the strain gauge principle, as well as the connection of position and angle sensors in potentiometric or DC/DC configuration. It also allows the measurement of process signals ± 1 V/ 5 V/ 10 V or 0 ...1 mA, 0(4) ... 20 mA .The present measured value is indicated on the 14 mm high LED main display, while a second display located directly below provides a reading of the peak value.
Due to the high accuracy of < 0.1 %, the display is particularly suitable for highly accurate measurements. Optionally, it is possible to monitor up to 4 setpoints and deliver the results via relay or transistor outputs. The display can therefore also be used for grouping as well as open and closed loop control. On activation of an external HOLD signal, the present measured value is frozen on the display. The TARE function is useful for balancing out previous loads, for example. The optional serial interface can be used to transfer measured values and perform device settings. Powerful PC software for this is available on request.
Description
State-of-the-art microprocessor technology has allowed the realization of numerous practical, special functions. Our devices provide operator guidance as a standard feature. Self-explanatory abbreviations greatly facilitate this process so that even inexperienced users are soon dispensed from the operating instructions. First, the type of input signal and type of sensor are specified. Interoperable are strain gauge units, potentiometers, process signals 0 ...1 mA, 4 ... 20 mA, ± 1 V and ± 10 V as well as DC/DC sensors. Then, the calibration process is selected.Users can choose between teach-in and calibration in accordance with sensor protocols. The decimal point can be moved as required. The sensor excitation stated in the technical specifications are set automatically on selection of the sensor type, except in case of process signals. A choice of three excitations is available for process signals. Complete electrical isolation of the measurement channel prevents measurement values from being falsified by ground loops.
burster präzisionsmeßtechnik gmbh & co kg ■ Talstr.1-5 D-76593 Gernsbach (P.O.Box 1432 D-76587 Gernsbach) Tel. +49-7224-645-0 ■ Fax 645-88
www.burster.com - info@burster.de