You may also be interested in
Rotary encoder, Displacement sensor, Interface, USB interface, Displacement transducer
Text version of the page
Untitled
table.main {}
tr.row {}
td.cell {}
div.block {}
div.paragraph {}
.font0 { font:4.00pt "Arial", sans-serif; }
.font1 { font:7.00pt "Arial", sans-serif; }
.font2 { font:8.00pt "Arial", sans-serif; }
8310 EN -4
Technical Data - Models 8315, 8316
Model
Order Code
Measurement Range
Measurement Error [% v.E.]
Max. System Pressure
[bar]
Max. Overload to One Side
[bar]
8315-100
0 ... ± 100 bar
< ±0.25
240
200
8315
8315-200
0 ... ± 200 bar
< ±0.25
340
400
8315-500
0 ... ± 500 bar
< ±0.25
640
750
8316-100
0 ... ± 100 bar
< ±0.5
240
200
8316
8316-200
0 ... ± 200 bar
< ±0.5
340
400
8316-500
0 ... ± 500 bar
< ±0.5
640
750
* Total error consisting of non-linearity, hysteresis and variation.
Electrical values
Dimensional drawing models 8315 and 8316
Bridge resistance: foil strain gauge Calibration shunt resistor:
The bridge output voltage, caused by a
is given in the calibration protocol. Excitation voltage: Sensitivity:
Environmental conditions Operating temperature: Nominal temperature range: Influence of temperature to zero signal:
model 8315
model 8316 Influence of temperature to characteristic:
model 8315
model 8316
350 Q , nominal 59 Q ± 0.1 % shunt resistor of this value
10 V DC or AC 2 mV/V, nominal
- 50 °C ...120 °C 15 °C ... 70 °C
< ± 0.5 % F.S./55 K
< ± 0.75 % F.S./55 K
< ± 0.5 % Rdg./55 K
< ± 1.0 % Rdg./55 K
M echanical values
Kind of measurement: Individual error: model 8315
measurement of differential pressure
non-linearity
hysteresis
variation
< ± 0.15 % F.S.
< ± 0.10 % F.S.
< ± 0.05 % F.S.
The differential pressure transducers are designed for a line pressure up to 140 bar and are designed for large pressure differences such as occur on double-acting hydraulic cylinders in construction machinery or material test devices. If the measuring range in the positive direction is restricted, the transducers can be used at a higher line pressure - up to the maximum value given in the table.
Thus the sensor that has a measuring range of ± 100 bar, when con-nected to 0 bar line pressure, operates over the range - 100 ... + 100 bar (figure 1), while when connected to 140 bar line pressure it operates from 40 ... 240 bar (figure 2). If the same sensor is connected to a 240 bar line pressure, only the range from 140 bar ... 240 bar is available for measurements (figure 3).
model 8316
non-linearity < ± 0.25 % F.S.
hysteresis < ± 0.13 % F.S.
variation < ± 0.07 % F.S.
Dynamic load: recommended 70 % of nominal load
possible 100 % of nominal load
Design:
Both pressure chambers are sealed hermetically, the membranes are welded. The outer caps of the pressure chamber are bolt. They are sealed by O-rings, made of metal. Mounting:
One side of the differential pressure transducer, opposite to the connector, has a mounting hole. Internal thread 10 - 32 UNF, 9.5 mm deep.
Material: stainless steel 17-4 PH (similar to 1.4542)
Pressure connector: internal thread 1/4 - 18 NPT
Electrical connector:
6 pin bajonett lock Souriau 851 - 07A - 10 - 6P
Wiring (standard):
pin A + B excitation voltage positive
pin C + D excitation voltage negative
pin E output signal negative
Stift F output signal positive
Mating connector:
Souriau 851-06E-C-10-6S
Model 9945 or Amphenol 62GB-16F-10-6S in scope of delivery refer to dimensional drawing approx. 1.8 kg
Dimensions:
Weight:
For any applications of the differential pressure sensors, care must be taken to ensure that the value for „overload, one side" is not ex-ceeded.
If the line pressure changes, the sensor's zero point moves. The shift in the zero point is reproducible and is in most cases less than 2% of full-scale. It is normal and is compensated for a static pressure 140 bar on both sides.
Order Code
Refer to table, additionally please mention options with short terms. Options
Option ...-V2xxxxxx
Internal amplifier with voltage output - 5 V...+ 5V DC
technical data refer to data sheet 83-IMV
Option ...-V4xxxxxx
Internal amplifier with current output 4...20 mA;
Ap = 0 bar = 4 mA, Ap = full scale positive == 20 mA
technical data refer to data sheet 83-IMV
Option ...-Vxx1xxxx
Extension of max. pressure of system to 200 bar;
maximum overload for one side: 100 bar Option ...-Vxx2xxxx
Extension of max. pressure of system to 345 bar;
maximum overload for one side: 100 bar,
only available for range > 0 ... ± 500 mbar
Accessories
Connecting cable for sensors with bridge output, complete with coupling plug and socket, 6-core, screened, bending radius > 5 mm, PVC insulation, standard length 3 m
for any type of burster analysis electronics in desktop housing with 12-pin connection Model 9911
with open, color-coded and tinned cable ends Model 9986
Technical changes reserved -
Latest updates of data sheet always under www.burster.com
burster praezisionsmesstechnik gmbh & co kg • Tel. +49-7224-6450 • Fax 64588 Talstr. 1-5 ^ D-76593 Gernsbach • www.burster.com • info@burster.com
|
|