Data Sheet Model 8527 - 2 Pages

Add to MyDirectIndustry favorites
Data Sheet Model 8527

Catalog excerpts

High Precision Compression Load Cell Model 8527 Application High quality sensors are required due to the constantly rising demand in accuracy and reliability in almost all technical fields. In addition to particularly small linearity errors, measuring applications often call for improved reversal errors, longtime stability and temperature constancy. This highly precise load cell in combination with qualitatively adequate evaluation electronics can solve many ambitious force measurement tasks. Its area of application is also extended to include today’s various needs of exact reference systems for quality control. Examples of application: ► Reference sensor for adjustment and control of force measurement facilities in production and in laboratories ► Material testing ► Spring fame force measurements ► Press-in operating ► Weighing technology ■ Measuring ranges from 0 ... 500 N to 0 ... 100 kN ■ Very high linearity < 0.05 % F.S. ■ Highest precision and manufacturing quality ■ Static and dynamic measurements ■ Protection class IP65 ■ Made of high quality stainless steel ■ With standardized output signal ■ WKS (Factory Calibration Certificate) or DKD/DAkkS (Deutsche Akkreditierungsstelle GmbH -German Accreditation Body) calibration optional ■ Simplest mounting Description The high precision load cell model for compression forces consists of a circular body, in which a load button is integrated. The load to be measured is transferred via its convex surface to the measuring element where it is converted into an electrical voltage by a strain gauge full bridge. The output voltage is proportional to the measuring force. The measuring element is located between two stabilizing membranes protecting the central part from lateral displacement when subjected to lateral force. A high level of measurement accuracy requires force application using a flat and hard stamp or plate while the load cell is mounted on a plane surface. The surface should be polished or even lapped and hardened. Its thickness should correspond to the forces in order to prevent bending. The force should be applied axially and centrically. Even if smaller angle errors influence the measuring signal, they are minimized by the convex and plane surface of the load application button. Two laterally located M8 threaded holes support the handling and transport of the sensor. Technical changes reserved. All data sheets at www.burster.com burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 Gernsbach 76593 Phone +49-7224-6450 info@burster.com

 Open the catalog to page 1

Electrical values Bridge resistance (full bridge): foil-model strain gauge 350 Q Excitation: max. 10 V DC or AC Calibration resistor (burster model 1148-6080): 80 kQ; 0.1 % The bridge output voltage resulting from a shunt of this value is stated in the calibration certificate. Environmental conditions Temperature compensated: Temperature operating: Temperature effect zero: Temperature effect span: Mechanical values Non-linearity: Kind of measurement: Deflection, full scale: Overload safe: Overload burst: Dynamic performance: permitted maximum Material: Protection class EN 60529: < ± 0.05 %...

 Open the catalog to page 2

All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures

  1. Digital Display

    4 Pages

  2. DIGILOW

    2 Pages

  3. Amplifier

    2 Pages

  4. TYP 9250

    6 Pages

  5. Load cells

    25 Pages

  6. Torque Sensors

    9 Pages

  7. Model 8709

    2 Pages

  8. Load cells

    25 Pages

  9. Model 1282

    2 Pages

  10. 1144-Pt

    2 Pages

  11. ForceMaster

    4 Pages

  12. 9243

    2 Pages

  13. DIGIFORCE® –

    9 Pages