POLYSNAP
® >
POWER INLET MODULES
VERTICAL MODULE ARRANGEMENT Inlet with 2.8mm or 6.3mmtags Single pole circuit breaker Illuminated (red or green)and non-illuminated rockerswitch 125Vac and 250Vac Neons BZV03/Z0000/C1/T 6.3mm tabs on CircuitBreaker
Panel Thickness: 1.0, 1.5, 2.0, 3.0mm. BZVxx/ Zxxxx/ xx xHow to Order
Type of Inlet Filtered or Non Filtered Switch Button Trip Current >
IEC CONNECTORS C14 power inlet (cold condition), 6.3 or2.8mm tabs: Z0000 = Non FilteredAxxxx = Standard C1 = non-illuminated
C2 = red neon (125Vac)C3 = green neon (125Vac)
C4 = red neon (250Vac)C5 = green neon (250Vac) Q = 5.0A
T = 8.0AU = 10.0A
X = 15.0A 03 = PX0575/63 04 = PX0575/28C16 power inlet (hot condition), 6.3 or 2.8mmtabs: 05 = PX0595/63 For Filtered inlet use 6th to 9thcharacters from filter ordering codesee page 113.E.g. BZV03/ 06 = PX0595/28 Please note type 05 and 06 are not available infiltered version A0120 /C1/T Note: For technical details of individual components also see page 92 >
Trip Curves % 1000900
800
700
600
500400300
200135
10000.1 1 10 100 1000 10000 Capacity Correction Factors for Ambient Temperatures Current Rating 5 to 15A Temperature ËšC-10-20-25-30-40-50-60Correction Factor.90.951.001.101.321.612.15 >
Load Current as a Percentof Circuit Breaker Rating Circuit Breaker Approvals: >
Time in SecondsTrip Curves are Specified at 25ËšC/77ËšF www.bulgin.co.uk 97 >