BUCHER
HYDRAULICS
Unloading Valve, Size 4 (accumulator charging valve) Series DWPB-4N-4 ...
• 250 bar, 30 l/min
• Separate ports for tank and pilot
drain
• ON/OFF difference unaffected by tank-line back pressure
• BUCHER cavity type AN
• Surface protection: - all external parts A3C to ISO 4042
1. Description
This unloading valve is a screw-in car­tridge for the AN mounting cavity and uses the 3/4"-16 UNF mounting thread. When the pressure at control port 1 rises to the preset upper switching pressure, the valve unloads pressure at port 4 via port 3 to tank. When the pres­sure at 1 falls to the lower switching pressure, the valve closes the connec­tion 4 == 3 (see Ordering code for the ON/OFF pressure differentials that are
available). The valve simultaneously functions as a two-stage pressure relief valve that protects the pump. Because ports 2 and 3 are run back to tank sep­arately (= external drain), the ON/OFF difference (bar) is unaffected by any back pressure in port 3. For customers who manufacture their own manifold blocks or plates, we offer form tool sets for sale or hire. The GANA body with threaded ports is available for pipe-mounting applications.
2. Symbols
DWPB-4N-4 i 1
3
l!
4
2
3. Main characteristics
Designation
unloading valve
Design
combined ball-seat / spool type
Mounting method
screw-in cartridge
Size
nominal 4 mm, BUCHER cavity type AN
Weight
kg
0.17
Mounting attitude
unrestricted
Flow direction
4 == 3, see symbol
Operating pressure range
bar
... 250, pilot oil at 2 to tank without back pressure
Pressure adjustment range
bar
pressure range 25 = 50 ... 250 pressure range 10 = 20 ... 100 pressure range 04 = 10 ... 040 see Performance graphs
Flow rate, Qmax
l/min
30
Fluids
HL and HLP hydraulic oils to DIN 51 524; for other fluids, please consult BUCHER
Fluid temperature range
°C
-25 ... + 80
Ambient temperature
°C
- 25 ... + 80
Viscosity range
mm2/s (cSt)
10 ... 550; recommended 15 ... 250
Minimum fluid cleanliness level
16/13 to ISO 4406 / CETOP RP70H; 8 ... 9 to NAS 1638
1/5