Internal Gear Unit for motor/pump service Series QXEM
Open the catalog to page 12/12 100-P-000225-EN-00/04.2017 Internal Gear Unit QXEM
Open the catalog to page 2Product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Main characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Performance graphs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum speed...
Open the catalog to page 34/12 100-P-000225-EN-00/04.2017 Internal Gear Unit QXEM
Open the catalog to page 41 General 1.1 Product description For applications requiring variable-speed multi-quadrant operation, Bucher Hydraulics has developed a special version: The QXEM internal gear drive unit. One of the central points in the QXEM series is its symmetric construction, with identical high and low pressure areas. With special metering grooves and lubrication systems as well as two same-size pressure-tight connections, the design is specially optimised for 2 and 4 quadrant modes and is thus ideally suited to both directions of rotation at high and low pressures. Thanks to the use of high-precision...
Open the catalog to page 5BUCHER hydraulics 2.2 Main characteristics IMPORTANT: The main characteristics are valid for hydraulic oils DIN 51524 with a viscosity of 42mm2/s. 1) Intermittent pressure for max. 20 sec/min but not more than 10% of the duty cycle. 2) Theoretical value at the maximum permitted continuous pressure. For starting torques, see section 3. 3) Minimum inlet pressure 0,98 bar absolute. 3.1 Minimum speed limit for pump and motor operation □ continuous operation □ intermittent operation 1) □ intermittent operation of max. 5 sec. □ intermittent operation of max. 2 sec. 1) Intermittent pressure for...
Open the catalog to page 6Measured to DIN 45635 part 26 in low-echo noise measurement chamber, valid for single units with deviations of ± 1,5 dB [A]. 3.2.1 QXEM22 100-P-000225-EN-00/04.2017 Internal Gear Unit QXEM
Open the catalog to page 73.3 Efficiency (ƞ) Measured with viscosity 42 mm2/s, speed 1450 min-1 Solid line = continous pressure / dashed line = max. intermittent pressure Volumetric efficiency Hydro-mechanical efficiency
Open the catalog to page 84 Dimensions Frame size 1) For SAE J518 code 61 bzw. ISO6162-1 pipe flange dimensions see section 10 2) For other shaft ends, contact Bucher Hydraulics 3) Threaded ports to DIN 3852 Part 2 1 Option 66 = 4-hole mounting flange ISO 3019/2 9/12 100-P-000225-EN-00/04.2017 Internal Gear Unit QXEM
Open the catalog to page 9Internal gear unit Frame size Pressure range Direction of rotation, unrestricted (to be inserted by the factory, see section 5.3 for a selection) 5.1 Ordering example Required: Displ./Consump.: Continuous pressure: For use with mineral oil: Ordering code: internal gear drive unit QXEM 40 cm3/rev 210 bar HLP QXEM 52-040 N 5.2 Standard configuration • Direction of rotation - unrestricted • 2-hole mounting flange to ISO 3019/1; Frame size QXEM 3-6 2-hole mounting flange to ISO 3019/2; Frame size QXEM 2+8 • Nitrile seals • Cylindrical shaft end to ISO R775 • Separate drain port in rear cover of...
Open the catalog to page 106 Fluid cleanliness QXEM internal gear units require a fluid with a minimum cleanliness level of NAS 1638, Class 9 or ISO 4406, code 20/18/15. We recommend the use of fluids that contain anti-wear additives for mixed-friction operating conditions. Fluids without appropriate additives can reduce the service life of pumps and motors. The user is responsible for maintaining, and regularly checking, the fluid quality. Bucher Hydraulics recommends a load capacity of > 30 N/mm2 to Brugger DIN 51347-2. 7 Note This catalogue is intended for users with specialist knowledge. The user must check the...
Open the catalog to page 1110.1 Pipe flanges - high pressure type - max. operating pressure 420 bar - Material ST37 / Viton seals (on request) - flange size SAE J518 code 61 / ISO 6162-1 Threaded pipe flanges are spot-faced for DIN 2353 pipe fitings Material 1) We recommend the use of seamless precision steel tube to DIN 2391 with-wallthick. max 6 mm info.kl@bucherhydraulics.com www.bucherhydraulics.com © 2017 by Bucher Hydraulics GmbH, D-79771 Klettgau Alle Rechte vorbehalten. Die angegebenen Daten dienen allein der Produktbeschreibung und sind nicht als zugesicherte Eigenschaften im rechtlichen Sinne zu...
Open the catalog to page 12All BUCHER Hydraulics catalogs and technical brochures
-
APM212HP
56 Pages
-
APM212
56 Pages
-
QXM42-HS
8 Pages
-
QXM-Mobil
8 Pages
-
AP312-HP
46 Pages
-
AP250-HP
46 Pages
-
AP212-HP
56 Pages
-
AP300
22 Pages
-
AP212
60 Pages
-
AP100
28 Pages
-
AP05
26 Pages
-
Qx series
36 Pages
-
QXV series
8 Pages
-
QXP
8 Pages
-
QXM series
16 Pages
-
DVs series
5 Pages
-
DWPB
7 Pages
-
QXEH series
12 Pages
-
Hydraulic Elevator Drives
4 Pages
-
SDDA ... S
4 Pages
-
QX3
32 Pages
-
Pressure Unloading Valve
7 Pages
-
Cartridge Valves
2 Pages
-
QXT series
8 Pages
-
DVS series
5 Pages
-
DWP
6 Pages
-
APM series
56 Pages
-
AP series
26 Pages
-
BH_Imageflyer_EN_2011
18 Pages
-
High Pressure Flow Divider
5 Pages
-
Flow Divider Series MTDA
4 Pages
-
Load Control Valves
164 Pages
-
Hydraulic Units UP 100
144 Pages
-
Internal Gear Pump
32 Pages
-
Hydraulic Units UP 110
24 Pages
-
Hydraulic Units UP 50
38 Pages
-
D.C. Electro-pumps, series ET
32 Pages
Archived catalogs
-
Check valves, size 06 ... 20
4 Pages
-
External gear pumps, series AP
96 Pages