Group: Bucher
Catalog excerpts
200 - P - 991223 - E - 00 / 04.04 1/24 Hydraulic Units UP110 motion and progress
Open the catalog to page 1200 - P - 991223 - E - 00 / 04.04 2/24 Contents General specifications 3 1 Power pack housings 4 2 Gear pumps 5 3 Tanks 6 4 Suction/return assembly kits for plastic tanks 8 5 Electric motors 10 6 Drives 13 7 Cartridge valves 15 8 Example of hydraulic power pack ordering code 23
Open the catalog to page 2200 - P - 991223 - E - 00 / 04.04 3/24 General specifications The positive experience acquired on the UP100 project, allowed us to develop a new and advanced hydraulic unit named UP110. It’s specifically designed for all machine applications requiring single acting actuators. The UP110 does not replace UP100 range but it is a completion of the same. Main features Single acting circuit: Available as single acting circuit solenoid operated normally closed or normally open or manual operated normally closed Very compact dimensions Two housing sides completely free (no assembled parts). Easy...
Open the catalog to page 3200 - P - 991223 - E - 00 / 04.04 4/24 1 Power pack housings 1.1 Single acting circuit: electric control version Cavity a = VM (Relief Valve) Cavity c = MF* (Multifunction valve) C1= hold check function C2= flow control function if needed C3= unloading function A M P T T Normally open Normally closed A M P T T 40 30.5 (1.2") 95.5 (3.76") 132.5 (5.22") 82 (3.23") cavity a c cavity port M port A 123 190 (7.48") (TVS version) 117.4 (4.62") M10 117.4 (4.62") 15 (.6") 133 (5.24") 110(4.33") 98.3 (3.87") 6 (.24") 3 (.12") 15 (.6") 40 (1.57") O-Ring 6425 Ø 107.32x5.34 NBR70 Suction port 3/8" BSP ø...
Open the catalog to page 4200 - P - 991223 - E - 00 / 04.04 8/24 3.5 Tank fixing kits Fixing kit for plastic tank up to 2.5 litres capacity, Code 200.7719.0015.0 200.5441.16021 Tank fixing clip 200.6774.0040.0 Tank fixing bracket (q.ty 2) 200.6711.0010.1 Bracket spacer (q.ty 2) 200.5212.03007 M6X18 fixing bolt (q.ty 2) Fixing kit for plastic tanks 3.5 litres capacity, Code 200.7719.0016.0 200.5441.16021 Tank fixing clip 200.6774.0040.0 Tank fixing bracket (q.ty 2) 200.6711.0010.1 Bracket spacer (q.ty 2) 200.5212.03007 M6X18 fixing bolt (q.ty 2) To assemble the vertical tanks do not use the tank fixing clip code...
Open the catalog to page 8200 - P - 991223 - E - 00 / 04.04 10/24 5 Electric motors 5.1 D.C. Electric motors Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 V (24 V) Nominal Power: . . . . . . . . . . . . . . . . . . . . 1600 W (2200 W) Protection index: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP44 Insulation class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F Brushes kit . . . . . . . . (12V-1600) code 200.5441.38022 . . . . . . . . . . . . . . . . . . . (24V-2200) code 200.5441.38023 Motor Motor with relay Clockwise Rotation 158.5 ø 112 90...
Open the catalog to page 10200 - P - 991223 - E - 00 / 04.04 15/24 7 Cartridge valves 7.1 General information This chapter includes all technical information relating to valves for use in conjunction with the housings described in the section 1. Complete the designation codes for the selected valve according to the technical information and guidelines given for each component. 7.1.1 Materials Bucher Hydraulics cartridge valves are manufactured using steel of high mechanical strength. Friction and potential wear are minimized by special heat treatments. Surface heat treatments protect parts exposed to the external...
Open the catalog to page 15200 - P - 991223 - E - 00 / 04.04 16/24 7.2 Pressure relief valve Direct acting Equilibrated piston Adjustable setting 4 setting pressure range Max. pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 bar Max flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 l/min Temperature range . . . . . . . . . . . . . . . . . . . . . . . -20/+90 C Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.120 Kg P T T P (3.46") (1.57") (1.89") (.33") (1.14") 40 48 29 88 M14x1.5 M20x1.5 8.5 The valve can be sealed against tampering...
Open the catalog to page 16200 - P - 991223 - E - 00 / 04.04 17/24 7.3 Solenoid operated directional valve: MF** (multifunction valve) - Normally closed Normally closed Poppet type Direct acting Flow from P to A (solenoid not energized) Flow from A to T (el. motor must be OFF) M24X1.5 63.5 (2.50") 88.5 (3.49") 74.3 (2.93") 18 (.71") 4.5 (.18") 19 (.75") 36 (1.42") 52 (2.04") C.C. 8 (.32") A P T A P T Push ¨ Cartridge for VRC flow control function Cartridge without VRC flow control function With manual override (TVSE versions) 63.5 (2.50") 88.5 (3.49") -5 35 + 7 Nm ø P T A 63.5 58.5 ( 2.3") C.A. 23.5 (.92") P T A...
Open the catalog to page 17200 - P - 991223 - E - 00 / 04.04 18/24 Electrical version VAL MF - TVS / 09FC - 23 - HC Multifunction valve MF Normally closed TVS Normally closed with manual override TVSE Connector type DIN 43650 HC Flow control function Tolerance:± 15 % Type Voltage Tolerance:± 10 % Type 2 l/min 02FC 12 VDC 13 3 l/min 03FC 24 VDC 23 4 l/min 04FC 24 VAC 21 5 l/min 05FC 110 VAC 41 6 l/min 06FC 220 VAC 51 9 l/min 09FC Mechanical part only P.M. 11 l/min 11FC (without coil and connector) 12 l/min 12FC 16 l/min 16FC Without flow control function 00FC 7.4 Solenoid operated directional valve: MF** Normally...
Open the catalog to page 18200 - P - 991223 - E - 00 / 04.04 19/24 Pressure drops: valve assembled in UP110 body Oil: Viscosity 37 mm2/s at 40 C (normally closed version) Operating limit l/min. 25 20 15 10 5 0 0 50 100 150 200 Max. flow rate depending by nominal pressure bar 20 16 12 8 4 0 0 5 10 15 20 25 l/min. 230 bar P-T 22 Electrical Version VAL MF - TOS / 00FC - 23 - HC Multifunction valve MF Connector type DIN 43650 HC Voltage - Tolerance:± 10 % Type Normally open TOS 12 VDC 13 Normally open with TOSE 24 VDC 23 manual override 24 VAC 21 110 VAC 41 Flow control function 220 VAC 51 Not allowed with the normally...
Open the catalog to page 19200 - P - 991223 - E - 00 / 04.04 20/24 Oil: Viscosity 37mm2/s at 40C A (normally closed version) bar 20 16 12 8 4 0 0 5 10 15 20 25 l/min. A-T P-A Pressure drops: valve assembled in UP110 body Manual performances Max. pressure 230 bar Max recommended pressure 210 bar Max. flow 25 l/min. Internal leakage 0-5 drops/min. Temperature range -20/+90 C O-Ring kit code 200.7742.0036.0 A 10 B C 10 10 B C A 5 A C = Microswitch ON A B = Hydraulically operated Threaded pin allows the lever stick be assembled in two different position. 10 5 C13 C14 A 10 B C 10 10 B C A 5 A B = Microswitch ON A C =...
Open the catalog to page 20All BUCHER Hydraulics catalogs and technical brochures
-
APM212HP
56 Pages
-
APM212
56 Pages
-
QXM42-HS
8 Pages
-
QXM-Mobil
8 Pages
-
AP312-HP
46 Pages
-
AP250-HP
46 Pages
-
AP212-HP
56 Pages
-
AP300
22 Pages
-
AP212
60 Pages
-
AP100
28 Pages
-
AP05
26 Pages
-
Qx series
36 Pages
-
QXV series
8 Pages
-
QXP
8 Pages
-
QXM series
16 Pages
-
QXEM
12 Pages
-
DVs series
5 Pages
-
DWPB
7 Pages
-
QXEH series
12 Pages
-
Hydraulic Elevator Drives
4 Pages
-
SDDA ... S
4 Pages
-
QX3
32 Pages
-
Pressure Unloading Valve
7 Pages
-
Cartridge Valves
2 Pages
-
QXT series
8 Pages
-
DVS series
5 Pages
-
DWP
6 Pages
-
APM series
56 Pages
-
AP series
26 Pages
-
BH_Imageflyer_EN_2011
18 Pages
-
High Pressure Flow Divider
5 Pages
-
Flow Divider Series MTDA
4 Pages
-
Load Control Valves
164 Pages
-
Hydraulic Units UP 100
144 Pages
-
Internal Gear Pump
32 Pages
-
Hydraulic Units UP 50
38 Pages
-
D.C. Electro-pumps, series ET
32 Pages
Archived catalogs
-
Check valves, size 06 ... 20
4 Pages
-
External gear pumps, series AP
96 Pages