Type 810 Magnetic level gauges Brooks Instrument - Brooks Instrument - #39 |
|
|
catalogue search
|
You may also be interested in
Control valve, Pressure controller, Mass flow-meter, Liquid flow-meter, Magnetic level switch
Text version of the page
Data Sheet
DS-MLG-810-eng
June, 2008 Magnetic level gauge
Page 37
Type 810
4-20mA Output / Level transmitter
Housings selection
Type Standard IP65
Dimensions (Lxlxh) 80mm x 75mm x 57mm
Material Aluminium
Rod Ø 14mm 316L St. St. on ¾" NPT brass connection
Connection PG9 Polyamid cable gland for Ø 5 à 9mm cables
Protection IP65 – 4 screws cover
Coating Polyester paint
Type B4 – Explosion proof ("d")
Dimensions (Lxlxh) See below drawing
Material Aluminium
Rod Ø 14mm 316L St. St. ¾" NPT
Connection ¾"NPT Aluminium cable gland (Ø 5 à 12mm cables)
(supplied) ATEX certified ("d")
Protection IP65/IP66 – screwed cover
Coating No – Raw Aluminium finish
Certificate ATEX N° LCIE01ATEX6060X
Marking*** II 2G EExdIICT6
Electrical data Supply Max.: 230V
Current Max. : 15A
Power Max. : 20W
Temperature Ta = -40°C = +75°C
Name plate Aluminium / St. St rivets
Type Intrinsically safe ("ia")*
Dimensions (Lxlxh) See below drawing
Rod Ø 14mm 316L St. St. on ¾" NPT brass connection
Connection PG9 Polyamid blue cable gland for Ø 5 à 8 m cables
(EExe certified)
Protection IP65
Coating Polyester paint
Certificate ATEX N° LCIE05ATEX6034X
Marking ** II 1 G EExiaIICT6/T5/T4
Electrical data Ui30V; li101mA; Pi758mW
Or Ui28,4V; li116mA; Pi824mW
Ci=0nF ; Li=0mH
Temperature T6: Ta=50°Cmax./ T5:Ta=65°Cmax./ T4: Ta=80°Cmax.
Plaque signalétique Aluminium / St. St rivets
Type ISA - 316L St. St.
Dimensions (Øxh) Ø 103mm, h=117mm
Rod Ø 14mm 316L St. St.
Connection M20x1,5 cable gland (cables Ø 5 à 9mm)
Protection IP67– screwed cover
Coating No - Raw Stainless steel finish
Explosion proof "d"certified version
Marking *** II 2G EExdIICT6
Certificate ATEX "d"
Connection M20x1,5 cable gland "d" certified
Protection IP67– screwed cover
Coating No - Raw Stainless steel finish
* The transmitter electronical unit must be choosen among the ATEX IS certified units (see next page)
** The ATEX marking complies with the 94/09/EC Directive and certify the transmitter, the reed switch line and the housing.
*** The ATEX marking complies with the 94/09/EC Directive and certify the reed switch line and the housing
|