1 Data Sheet DS-VA-MT3600-eng December, 2008 Models MT3600, MT3601 & MT3602 Features and Benefits • Flanged, NPT or socket-welded connections • 10% full scale accuracy • Disassembly for cleaning without removal from the process line • Standard direct reading, detachable scales • Permanent magnetic link between metering float and indicator/alarm • CSA- US and Canada Description The Brooks® MT3600, MT3601 and MT3602 armored flowmeters are designed to be reliable and economical high flow rate purge meters with 10% accuracy. These meters are especially useful for metering coolants, pump seal fluids, lubricants under pressure, and opaque fluids. The flow rate is measured by the movement of a tapered plug in a fixed orifice. Indication is by an external tubular follower coupled magnetically to an extension of the tapered plug. A certified explosion-proof/intrinsically safe alarm is optional. Specifications Capacities and Pressure Drops Refer to Table 1 Accuracy Standard Flow Accuracy: ±10% Full Scale from 100% to 10% of scale reading Optional Flow Accuracy: ±5% accuracy Repeatability 1.0% Full Scale Pressure Ratings Refer to Table 2 for maximum non-shock pressure Scales Standard: Detachable aluminum plate Length: 1.5 inches (38 mm) Graduations: Choice of direct reading units, milimeter or percentage of maximum flow with regulator tag Optional: Dual scales Ambient Temperature Limits -20°F to 122°F (-29°C to 50°C) Model MT3602 Armored Flowmeter with Indicator Model MT3600 with AP Alarm Brooks® MT3600 Series Metal Tube Variable Area Flowmeters Table 1 Capacities and Pressure Drop 1. All air flows given are at 14.7 psia and 70°F. 2. 1" and 1-1/2" meters not recommended for gas service, due to stability of float. 3. Minimum operating pressure (downstream) on gas service is 35 psig for 1/2" size. Consult factory for other conditions. Size 8 Size 10 (1") Size 12 (1-1/2") Pressure Pressure Pressure Air Water Drop Water Drop Water Drop scfh gph psi gpm psi gpm psi 23 5 _ 5 1.75 20 2.00 58 15 1.25 _ _ 30 2.75 120 30 1.50 10 3.75 40 4.75 195 50 1.00 15 4.75 50 5.75 425 100 1.50 _ _ _ _ 790 180 3.25 _ _ _ _ 1660 300 5.00 _ _ _ _

pageCatalog pdf di En 2012-02-06-10