You may also be interested in
Pressure regulator, Pressure gauge, Mass flow-meter, Pressure transducer, Variable area flow-meter
Text version of the page
©2009 Brooks Instrument, LLC 153-30648-000 Rev 001 (08/09)
For technical assistance, contact Brooks Instrument Applications Engineering at 972.359.4000.
3.278
5.000
4.882
1.207
.184
1.500
IN SERIES SEMATECH
1.504
38.2 mm
.732
18.6 mm
2X M4 X 0.7-6H
1.000
25.4 mm
45°
2X M5 X 0.8-6H
4.450
1.500
1.207
5.000
3.666
4.882
ANALOG DEVICENET
NOTE: Please contact Brooks Instrument product management for other configuration options.
All dimensions in inches unless otherwise stated. Multiple standards exist for mounting
hole locations which will vary between manufacturers and model generations. Contact
Brooks Product Mgmt for help with your application.
Example:
GF100 C XX C SH40 010C VX A O *DX XXXX A A 000
VX
CX
DX
WX
YX
AX
BX
LX
A
V
DX
EX
GX
G1
KX
BB
XXXX
===>
SH40
SH41
SH42
SH43
SH44
SH45
SH46
SH47
SH48
===>
010C
030C
092C
280C
860C
2.6L
7.2L
015L
030L
GF100
Configurable
Gas Specific
Flow Ranges from 3 sccm–30 slpm N2 Equivalent
Standard Application
Normally Closed Valve
1-1/2" VCR 1/4"
1-1/8" C Seal 92mm
1-1/8" C Seal 80mm
1-1/8" W Seal 92mm
1-1/8 W Seal 80mm
1-1/2" C Seal 92mm
1-1/2" W Seal 92mm
1-1/8" C Seal 92mm w/Poke Yoke
Atmosphere
Vacuum
Auto Shut Off (Included)
Auto Shut Off (Not Included)
Customer Special Request Number
Standard Flow Sensor
Specify Gas Code and Range, i.e. “0004” = Argon and “010L” = 10 slpm
Standard Configuration # 40, 3–10 sccm N2 Equivalent
Standard Configuration # 41, 11–30 sccm N2 Equivalent
Standard Configuration # 42, 31–92 sccm N2 Equivalent
Standard Configuration # 43, 93–280 sccm N2 Equivalent
Standard Configuration # 44, 281–860 sccm N2 Equivalent
Standard Configuration # 45, 861–2600 sccm N2 Equivalent
Standard Configuration # 46, 2601–7200 sccm N2 Equivalent
Standard Configuration # 47, 7201–15000 sccm N2 Equivalent
Standard Configuration # 48, 15001–30000 sccm N2 Equivalent
A
X
Auto Zero (Included)
Auto Zero (Not Included)
A
X
0°C Reference Calibration (Standard)
21°C Reference Calibration (Normal)
Customer To Specify Temperature
000
021
XXX
GF100 Product Configuration
C
C
X
O
XX
k d f h l l d
5 Pin DeviceNet™ M8
Cable Adapter to Cardedge (w/out VTP), RS485 through RJ11 Jacks;
Display & Overlay w/ 180° Orientation
9 Pin D with RS-485 (UDG9), Display/Overlay w/180° Orientation
9 Pin D with RS-485 (UDG9)
Cable Adapter to MKS 15 Pin D (UDK 15)
5 Pin DeviceNet™ M8 w/Analog
Brooks Instrument, LLC
915 Enterprise Boulevard
Allen TX 75013 USA
Telephone 972 359 4000
Facsimile 972 359 4100
www.BrooksInstrument.com
|
|