9
Data Sheet
DS-CM-QmB-eng
May, 2008 QmB Series IP40, IP65, IP65XP
Meter: 6.6 W
Additional Functions and Outputs
Damping: Factory set time constant from 0 to 10 seconds.
Alarms and Warnings: Alarms accessed via HART or the Brooks Service Tool can be configured
to monitor the following variables:
• Mass Flow
• Density
• Volumetric Flow
• Temperature
• Slug Flow
• Diagnostic Failure
• Setpoint Deviation
• Valve Drive
LED's: (11) 'STAT'
solid green: system operative.
solid red: system fault.
'AL'
flashing green: warning
flashing red: alarm
Pushbutton: (12) 'ZERO' setting pushbutton.
Notes (continued)
(10) If QUANTIM is configured for HART® communication protocol, only 4-20 mA I/O option is available.
(11) IP65 and IP65XP Series external housing cover must be removed to gain access to status LED's.
(12) IP65XP series external housing cover must be removed to gain access to zero push button.
TRADEMARKS
Brooks ......................................................... Brooks Instrument, LLC
Brooks Service Tool ...................................... Brooks Instrument, LLC
QUANTIM ................................................... Brooks Instrument, LLC
HART ....................................... HART Communications Foundation
Hastelloy .......................................................... Haynes International
Kalrez ......................................................... DuPont Dow Elastomers
Viton ............................................. DuPont Performance Elastomers
VCO .................................................................................. Cajon Co.
VCR .................................................................................. Cajon Co.
QUANTIM Patent Numbers as follows:
Argentina ............................................. AR026329B1, AR021594B1
Australia .................................................... 778137, 771345, 782183
China .................................. ZL00817949.2, ZL02823425.1, 171140
Federation of Russia .......................... 2272257, 2263284, 2277227
Germany ........................................................................ 40004270.3
Hong Kong ..................................................................... HK1051720
India ...................................................................................... 199406
Indonesia ......................................................................... ID0015789
Japan ................................................................... 1111950, 3904926
Malaysia ...................................................................... MY-128330-A
Mexico ....................................................... 242129, 244688, 231280
Singapore ..................................................... 88632, 81430, 103761
South Korea .......................................................................... 678430
Switzerland ............................................................................127118
UK ....................................................................................... 2092458
US ..................... D436876, 4843890, 4996871, 5231884, 5295084,
5555190, 5687100, 5929344, 6226195, 6476522, 6487507,
6505131, 6505135, 6512987, 6513392, 6526839, 6748813,
6769301, 7032462, 7111519, 7117751, 7114517, 7204679
Counterparts in other countries and other patents pending
|
|