You may also be interested in
Pressure controller, Liquid flow-meter, Bourdon tube pressure gauge, Flow-meter, Explosion proof flow-meter
Text version of the page
2
Brooks® Model MT 3810
Data Sheet
DS-VA-MT3810-eng
March, 2008
Table 1 Model MT 3810 Capacities, Pressure Drop and Viscosity Immunity Ceiling
MATERIALS OF CONSTRUCTION:
Metering Tube
316L stainless steel
Flanges and End Fittings
316/316L dual certified stainless steel
Connections
150 lbs or 300 lbs RF ANSI B 16.5 flanges or PN 40
DIN 2527/2635 or Female NPT
125/175 Ra flange finish
Vertical inlet and outlet
Floats
Standard: 316L stainless steel
O-rings (NPT only)
Standard: Viton® fluoroelastomers
Optional: Teflon®
Indicator Housing and Cover
Enclosure NEMA 4X construction
Die cast aluminum, polyurethane paint with glass
window
Meter Dimensions
Refer to Figure 1, Sizes 7-13
Ordering Information and Model Code
Refer to Table 4
OPTIONAL ACCESSORIES
Needle Valves and Sight Flow Indicators
For flowrate control, needle valves may be externally
piped into the inlet or outlet side of the instrument.
Needle valves can be supplied up to size 10 (1")
maximum 6.6 gpm (1,500 l/hr) water equivalent. Sight
flow indicators are available for all flanged meters and
to size 13 (2") NPT meters.
OPTIONAL ELECTRONIC EQUIPMENT
Electronic equipment available with the Model MT 3810
includes the Microprocessor Transmitter,
Microprocessor Transmitter/Alarm/Pulse Output for
totalization, Inductive Alarms, and Transmitter with
Inductive Alarms, refer to pages 5 through 16 for
additional information. All models are designed to be
either Intrinsically Safe or Explosion Proof.
CONNECTION SIZE FLOAT MATERIAL STAINLESS STEEL 316L
METER DIN ANSI FLOAT WATER AIR 1,2 Press Drop Press Drop VIC (cSt) Max. Visc PED
SIZE DN mm inches CODE l/h gpm scfm nm3/h mbar inches WC (cSt) (cSt) Category
15 1/2" A 25 0.11 0.49 0.78 30 13 1 40 SEP
B* 65 0.28 1.2 2 30 13 1 20 SEP
C 130 0.59 2.4 3.7 30 13 1 120 SEP
D* 200 0.88 3.7 5.8 35 15 1 20 SEP
15 1/2" A 250 1.1 5.2 8.2 45 19 2 250 SEP
B 400 1.7 7.7 12 55 23 1 180 SEP
C 650 2.8 11 18 60 25 2 475 SEP
D 1000 4.4 21 33 130 53 1.5 250 SEP
25 1" A 1200 5.2 19 30 60 25 5 475 CAT I, II or III
B 1500 6.6 31 49 70 29 1.5 400 CAT I, II or III
C 2400 10 41 65 85 35 7 475 CAT I, II or III
D 3500 15 65 100 155 63 4 475 CAT I, II or III
40 1 1/2" A 4000 17 67 100 50 21 50 475 CAT I, II or III
B 6000 26 94 140 60 25 30 475 CAT I, II or III
C 8000 35 150 230 150 61 2 475 CAT I, II or III
D 10000 46 210 330 300 121 2 475 CAT I, II or III
50 2" A 6500 28 100 160 50 21 50 475 CAT I, II or III
B 9500 41 160 250 60 25 50 475 CAT I, II or III
C 12000 55 200 310 100 41 2.5 475 CAT I, II or III
D 20000 88 390 620 300 121 1 475 CAT I, II or III
1. Air flows in scfm are given at 70°F and 14.7 psia 2. Air flows in nm3/h are given at 0°C and 1.013 bar (a)
3. *Minimum operating pressure required 7 psig / 0.48 bar
13
7
8
10
12
|
|