Brooks® IPT122 Series 2 Inch Stainless Steel Indicating Pressure Transmitters - Brooks Instrument - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for Brooks Instrument

Text version of the page
Brooks is a trademark of Brooks Instrument, LLC. All other product or service names mentioned in this document may be trademarks of the companies with which they are associated. System descriptions are typical and subject to change without notice. DS-PR-IPT122-eng (supersedes PF404 Rev. D) 04/10 2.28" [57.9 mm] 1.88" [47.8 mm] 2.20" [55.9 mm] 1.18" [30.1 mm] Cable Diameter: 0.23" FRONT VIEW SIDE VIEW 2.28" [57.9 mm] 2.16" [54.9 mm] 1.89" [48.0 mm] VM FACE SEAL MALE 1/4" VSM FACE SEAL SWIVEL MALE 1 /4" VSF FACE SEAL SWIVEL FEMALE 1 /4" NPT 1/4" 1.95" [49.5 mm] IPT122 2 Inch Stainless Steel Indicating Pressure Transmitter Specifications Case Material 300 Series Stainless Steel, electropolished Bezel and Lens Material One-piece polycarbonate, screw-on Socket 316L stainless steel Movement 300 Series Stainless Steel Bourdon Tube 316L Stainless Steel Proof Pressure 110% Burst Pressure 400% Connections Face-seal male, face-seal swivel male, face-seal swivel female and 1/4" NPT male Dial White with black marking. “Use No Oil” is red Accuracy 1% of full scale Helium Leak Check 4 x 10–9 Inboard Std. cc/sec Cleaning Cleaned for oxygen service to ANSI B40.1 level IV specifications Response Time Less than 200 milliseconds Operating (ambient) 0° to 160°F (–18° to 71°C) Compensating 20° to 135°F (–7° to 57°C) Storage –20° to 175°F (–29° to 79°C) Voltage In 11.5 to 30 VDC (12 VDC recommended) Voltage Stability Filtered power supply with noise < 2mV RMS, ripple < 6 mV P-P Operating Current 40 mA maximum short circuit to ground, 8 mA continuous load, 10 mA maximum intermitttent Output Voltage Type 1 0–5 VDC Type 2 1–5 VDC Type 3 1–5 VDC ground referenced Type 4 4–20 mA sinking Type 5 0–5 VDC or 1–5 VDC, or 4–20 mA current sink Type 6 1–5 VDC ground reference, 4–20 mA sinking Type 8 4–20 mA sourcing, 3 Pin Molex connector with 10’ cable Type 9 4–20 mA sourcing 6’ cab/w with tinned ends Output Current 40 mA max. short circuit to ground. 10 mA continous load. Transmitter Leads 2 m [6'] cable, tinned ends, 0.23" in diameter Pressure Ranges Available Vacuum to 4,000 PSI (276 bar). Metric also available (See chart on the left) Approximate Shipping Weight 8.5 lbs. (0.39 kg) Transmitter Type 1 = 0 to 5 Volts floating referenced 2 = 1 to 5 Volts floating referenced 3 = 1 to 5 Volts ground referenced 4 = 4 to 20 mA sinking 5 = Universal output 6 = 4 to 20 mA sinking. 1 to 5 VDC ground referenced 8 = 4 to 20 mA current sourcing. Example: R-250 Ohms 3 PIN connector. Signal at 4 mA: E = 1 Volt Signal at 20 mA: E = 5 Volt 9 = 4 to 20 mA current sourcing. Example: R-250 Ohms 3 wire cable. Signal at 4 mA: E = 1 Volt Signal at 20 mA: E = 5 Volt Pressure Connection VM = Face-seal male VSM = Face-seal swivel male VSF = Face-seal swivel female NPT = 1/4" NPT male Pressure Range See options in range charts below. Units PSI PSI/Bar MPa Bar PSI/KGC IPT122 * All figure intervals and smallest interval depicted in this chart represent typical artwork layout and may not be accurate for all gauges. Range Figure Intervals* Smallest Interval* 30–0–15 10 in Hg–3 psi 2 in Hg–1 psi 30–0–30 10 in Hg–5 psi 2 in Hg–1 psi 30–0–60 30 in Hg–10 psi 5 in Hg–2 psi 30–0–100 30 in Hg–20 psi 5 in Hg–2 psi 30–0–160 10 in Hg–25 psi 10 in Hg–5 psi 30–0–200 30 in Hg–40 psi 10 in Hg–5 psi 30–0–300 10 in Hg–50 psi 15 in Hg–10 psi Range Figure Intervals* Smallest Interval* 0–30 5 1 0–60 10 2 0–100 20 2 0–160 40 5 0–200 40 5 0–300 50 10 Range Figure Intervals* Smallest Interval* 0–400 100 10 0–600 100 20 0–1000 200 20 0–3000 500 100 0–4000 1000 100 NOTE: All ranges listed are in Hg and/or psi. If a scale other than Hg or psi is required, convert the pressure range code to the customer specified units and use that in the product description code when specifying the product. For dual range specify the range code for the first engineering unit ( Ex. For a dual range with units of KGC/KPA the range should be specified in KGC). Product Configurations Product Dimensions HELP DESK In case you need technical assistance: Americas 1-888-554-FLOW Europe +(31) 318 549 290 Asia +011-81-3-5633-7100

pageCatalog pdf di En 2012-05-20-14