Brooks® IPT122 Series 2 Inch Stainless Steel Indicating Pressure Transmitters - Brooks Instrument - #2 |
|
You may also be interested in
Magnetic level indicator, Digital controller, Coriolis flow-meter, Pressure transmitter, Valve
Text version of the page
Brooks is a trademark of Brooks Instrument, LLC. All other product or service names
mentioned in this document may be trademarks of the companies with which they are
associated. System descriptions are typical and subject to change without notice.
DS-PR-IPT122-eng (supersedes PF404 Rev. D) 04/10
2.28" [57.9 mm] 1.88" [47.8 mm]
2.20" [55.9 mm]
1.18" [30.1 mm]
Cable Diameter: 0.23"
FRONT VIEW SIDE VIEW
2.28" [57.9 mm] 2.16" [54.9 mm]
1.89" [48.0 mm]
VM
FACE SEAL MALE 1/4"
VSM
FACE SEAL
SWIVEL MALE 1 /4"
VSF
FACE SEAL
SWIVEL FEMALE 1 /4"
NPT
1/4"
1.95" [49.5 mm]
IPT122 2 Inch Stainless Steel Indicating Pressure
Transmitter Specifications
Case Material 300 Series Stainless Steel, electropolished
Bezel and Lens Material One-piece polycarbonate, screw-on
Socket 316L stainless steel
Movement 300 Series Stainless Steel
Bourdon Tube 316L Stainless Steel
Proof Pressure 110%
Burst Pressure 400%
Connections Face-seal male, face-seal swivel male,
face-seal swivel female and 1/4" NPT male
Dial White with black marking. “Use No Oil” is
red
Accuracy 1% of full scale
Helium Leak Check 4 x 10–9 Inboard Std. cc/sec
Cleaning Cleaned for oxygen service to ANSI B40.1
level IV specifications
Response Time Less than 200 milliseconds
Operating (ambient) 0° to 160°F (–18° to 71°C)
Compensating 20° to 135°F (–7° to 57°C)
Storage –20° to 175°F (–29° to 79°C)
Voltage In 11.5 to 30 VDC (12 VDC recommended)
Voltage Stability Filtered power supply with noise < 2mV
RMS, ripple < 6 mV P-P
Operating Current 40 mA maximum short circuit to ground,
8 mA continuous load, 10 mA maximum
intermitttent
Output Voltage
Type 1 0–5 VDC
Type 2 1–5 VDC
Type 3 1–5 VDC ground referenced
Type 4 4–20 mA sinking
Type 5 0–5 VDC or 1–5 VDC, or 4–20 mA
current sink
Type 6 1–5 VDC ground reference, 4–20 mA
sinking
Type 8 4–20 mA sourcing, 3 Pin Molex connector
with 10’ cable
Type 9 4–20 mA sourcing 6’ cab/w with tinned ends
Output Current 40 mA max. short circuit to ground. 10 mA
continous load.
Transmitter Leads 2 m [6'] cable, tinned ends, 0.23" in
diameter
Pressure Ranges Available Vacuum to 4,000 PSI (276 bar). Metric also
available (See chart on the left)
Approximate Shipping
Weight 8.5 lbs. (0.39 kg)
Transmitter Type
1 = 0 to 5 Volts floating referenced
2 = 1 to 5 Volts floating referenced
3 = 1 to 5 Volts ground referenced
4 = 4 to 20 mA sinking
5 = Universal output
6 = 4 to 20 mA sinking.
1 to 5 VDC ground referenced
8 = 4 to 20 mA current sourcing.
Example: R-250 Ohms 3 PIN connector.
Signal at 4 mA: E = 1 Volt
Signal at 20 mA: E = 5 Volt
9 = 4 to 20 mA current sourcing.
Example: R-250 Ohms 3 wire cable.
Signal at 4 mA: E = 1 Volt
Signal at 20 mA: E = 5 Volt
Pressure Connection
VM = Face-seal male
VSM = Face-seal swivel male
VSF = Face-seal swivel female
NPT = 1/4" NPT male
Pressure Range
See options in range charts below.
Units
PSI
PSI/Bar
MPa
Bar
PSI/KGC
IPT122
* All figure intervals and smallest interval depicted in this
chart represent typical artwork layout and may not be
accurate for all gauges.
Range Figure Intervals* Smallest Interval*
30–0–15 10 in Hg–3 psi 2 in Hg–1 psi
30–0–30 10 in Hg–5 psi 2 in Hg–1 psi
30–0–60 30 in Hg–10 psi 5 in Hg–2 psi
30–0–100 30 in Hg–20 psi 5 in Hg–2 psi
30–0–160 10 in Hg–25 psi 10 in Hg–5 psi
30–0–200 30 in Hg–40 psi 10 in Hg–5 psi
30–0–300 10 in Hg–50 psi 15 in Hg–10 psi
Range Figure Intervals* Smallest Interval*
0–30 5 1
0–60 10 2
0–100 20 2
0–160 40 5
0–200 40 5
0–300 50 10
Range Figure Intervals* Smallest Interval*
0–400 100 10
0–600 100 20
0–1000 200 20
0–3000 500 100
0–4000 1000 100
NOTE:
All ranges listed are in Hg and/or psi. If a scale other than
Hg or psi is required, convert the pressure range code to
the customer specified units and use that in the product
description code when specifying the product.
For dual range specify the range code for the first
engineering unit ( Ex. For a dual range with units of
KGC/KPA the range should be specified in KGC).
Product Configurations
Product Dimensions
HELP DESK
In case you need technical assistance:
Americas 1-888-554-FLOW
Europe +(31) 318 549 290
Asia +011-81-3-5633-7100
|
|