DS-PR-IPS122 -eng (supersedes PF403 Rev 001) 04/10
2.28" [57.9 mm] 1.88" [47.8 mm]
2.20" [55.9 mm]
1.18" [30.1 mm]
2.28" [57.9 mm] 2.16" [54.9 mm]
1.89" [48.0 mm]
Cable Diameter: 0.23"
FRONT VIEW SIDE VIEW
1.95" [49.5 mm]
1.32" [33.6 mm] 1.32" [33.6 mm] 1.32" [33.6 mm] 1.32" [33.6 mm ]
VM
FACE SEAL MALE 1/4"
VSM
FACE SEAL
SWIVEL MALE 1 /4"
NPT
1/4"
VSF
FACE SEAL
SWIVEL FEMALE 1 /4"
IPS122 Series 2 Inch Stainless Steel Indicating
Pressure Switches Specifications
Case Material 300 series stainless steel, electropolished
Bezel and Lens Material One-piece polycarbonate, screw-on
Socket 316L stainless steel
Movement 300 Series Stainless Steel
Bourdon Tube 316L stainless steel
Proof Pressure 110%
Burst Pressure 400%
Connections Face-seal male, face-seal swivel male,
face-seal swivel female and 1/4" NPT
male
Dial White with black marking “Use No Oil” is
red
Accuracy 1% of full scale
Helium Leak Check 4 x 10–9 Inboard Std. cc/sec
Cleaning Cleaned for oxygen service to ANSI
B40.1 level IV specifications
Response Time Less than 200 milliseconds
Operating (ambient) 0° to 160°F (–18° to 71°C)
Compensating 20° to 135°F (–7° to 57°C)
Storage –20° to 175°F (–29° to 79°C)
Switch Power Input
Off-On Switch Type 1 9 to 30 VDC
Logic Output 8 to 30 VDC
Type 2 9 to 30 VDC
Logic Output 5 VDC Type 3 4.8 to 5.2 VDC
Switch Power Rating
Off-On Switch Type 1 12 watts or 500 mA
175 mA max. for intrinsically safe applica
tions
Logic Output 8 to 30 VDC
Type 2 60 mA (sink). Open collector NPN
Logic Output 5 VDC Type 3 60 mA (sink). Open collector NPN
Output Voltage and Current Draw
Off-On Switch Type 1 0 to 9–30 VDC; 30 mA (off), 45 mA (on)
Logic Output 8–30 VDC
Type 2 0 to 9–30 VDC; 30 mA (off), 45 mA (on)
Logic Output 5 VDC Type 3 0 to 5 VDC; 3 mA (off), 11 mA (on)
Switch leads 2 m [6'] cable, tinned ends, 0.23" in
diameter
Switch Differential 3% of scale; 0.25% of scale repeatability
Trip Position External adjust. Select to trip on
ascending(N.O.) or descending (N.C.)
pressure. (Field changeable by internal
jumper.)
Pressure Ranges Available Vacuum to 4,000 PSI (276 bar). Metric
also available. Offered in single scale
only.(See chart on the left)
Approximate Shipping
Weight 0.65 lbs. (0.29 kg)
Pressure Connection
VM = Face-seal male
VSM = Face-seal swivel male
VSF = Face-seal swivel female
NPT = 1/4” NPT male
Pressure Range
See options in range charts below.
Units
PSI
PSI/Bar
MPa
Bar
PSI/KGC
IPS122
Switch Type
1 = Type 1
2 = Type 2
3 = Type 3
*Refer to specifications table for
output voltage and current draw.
Trip Position
A = Ascending (normally open)
D = Descending (normally closed)
* All figure intervals and smallest interval depicted in this
chart represent typical artwork layout and may not be
accurate for all gauges.
Range Figure Intervals* Smallest Interval*
30–0–15 10 in Hg–3 psi 2 in Hg–1 psi
30–0–30 10 in Hg–5 psi 2 in Hg–1 psi
30–0–60 30 in Hg–10 psi 5 in Hg–2 psi
30–0–100 30 in Hg–20 psi 5 in Hg–2 psi
30–0–160 10 in Hg–25 psi 10 in Hg–5 psi
30–0–200 30 in Hg–40 psi 10 in Hg–5 psi
30–0–300 10 in Hg–50 psi 15 in Hg–10 psi
Range Figure Intervals* Smallest Interval*
0–30 5 1
0–60 10 2
0–100 20 2
0–160 40 5
0–200 40 5
0–300 50 10
Range Figure Intervals* Smallest Interval*
0–400 100 10
0–600 100 20
0–1000 200 20
0–3000 500 100
0–4000 1000 100
NOTE:
All ranges listed are in Hg and/or psi. If a scale other than
Hg or psi is required, convert the pressure range code to
the customer specified units and use that in the product
description code when specifying the product.
For dual range specify the range code for the first
engineering unit ( Ex. For a dual range with units of
KGC/KPA the range should be specified in KGC).
Product Configurations
Product Dimensions
HELP DESK
In case you need technical assistance:
Americas 1-888-554-FLOW
Europe +(31) 318 549 290
Asia +011-81-3-5633-7100
|
|