Meters 124.1 for Speed, Ratio, Difference Versions C / D 124.100 for display onlyMeters 124.1 for Speed, Ratio, Difference Versions C / D 124.100 for display only - Braun Industrie-Elektronik - #1 |
|
You may also be interested in
Rotary encoder, Encoder, Eddy current sensor, Measurement converter, Displacement sensor
Text version of the page
Speed and Frequency Seite 1 von 1
Braun GmbH ISO 9001 certified Quality
Post-Office Box 1106 • D-71301 Waiblingen
Phone: +49(0) 7151 / 95 62-30 • Fax: +49(0) 7151 / 9562-50 • eMail: info@braun-tacho.de
Internet: www.braun-tacho.de
Meters 124.1 for Speed, Ratio, Difference
Versions C / D 124.100 for display only
Application Characteristics
· 2 measuring channels . Display selection by key.
· Facility to compute ratio, difference, sum of both channels.
· Reading all process variables w hich are transmitted as a series
of pulses or as AC-voltage. Compatible with all our speed sensors,
and many other transmitters for speed and flow.
· Preferred in power plants, with paper and textile machines, or
test installations, for their high accuracy and their facility to read
ratio and difference, in comparison with their second input.
Also, as part of larger systems, for remote display.
For applications requiring further facilities, we recommend our
extended versions (see separate sheets):
with setpoint alarms and analog output: series 124.112
with PROFIBUS communication: series 124.1S4
with Ex-proof enclosure: series D124Ex9
Measuring Principle
2 measuring channels , M and B, operate in parallel. Both use the
advantageous frequency measuring principle, distinguished by
pulse distance evaluation, automatically extended over a programmable
period of time. The ideal combination of tracking speed and
average, as appropriate for the application.
The unit precisely regards the relationship between the process
quantity (speed) and the transmitted frequency, by digital (scaling),
individually for both channels. Thus, any required reading can be
established.
Measuring accuracy ± 0.01 % ± 1 in last significant digit.
Minimum time extension for every measuring period programmable
30 millisec up to 10 seconds.
Composite Quantities
With the measured results from both channels M and B, the unit
continuously computes their ratio, difference, and sum. Thereby, a
total of 6 different quantities is held at the user’s
disposal:
Variable M
Variable B
Ratio M ÷ B
Difference M – B
Sum M + B
Percentage difference (M – B) ÷ B.
Any two of these can be selected to be alternatively displayed,
switched by key or external control. LED lights indicate the actually
valid display selection.
Sensor Signal Inputs
Both channels M and B provide two input paths, accepting all our
sensors. Both are isolated from power supply, and have common
zero.
The high level path responds with on/off >7/<4 volts. Max. signal
150 v. Impedance 100 k. Frequency 0-100 kHz.
The high sensitivity path responds to > 50 millivoltsRMS, max 35 v
DC may be superimposed. Max. signal 100 v.
Impedance 50 k. Frequency 1-50 kHz.
Sensor supply 12 volts/60 ma (common to both channels),
and 2x8 volts via 1k for 2leads NAMUR types.
Design
Two design versions are available, w ith identical functional characteristics.
Panel mount version ( C ):
Front frame 96x48 mm, protection grade IP50. Plastics enclosure,
depth 125 mm, mounting by supplied brackets. Panel thickness up
to 10 mm, opening 92x45 mm. Weight approx. 200 grams. Rear
side terminals for wire up to 2.5 mm2, protection grade IP20.
Snap-on-track version ( D ):
For DIN rail 35 mm. Plastics enclosure, protection grade IP50.
Length 100 mm, width 75 mm, height 111 mm. Weight approx. 200
grams. Terminals for wire gage up to 2.5 mm2, protection grade
IP20.
Display
5 digit (resp. 4 digits and minus sign), with bright red figures,
14 mm high. Decimals and blank zeroes can be programmed. The
display update sequence may be increased beyond the minimum
measuring period, for easier readability.
During the programming phase, the display reads the step number
and its corresponding parameter.
HOLD function
An external control signal, if active, holds the display at the most
recent measurement.
MAX/MIN memory
Maximum and minimum measurements are memorized to be called
to the display by keys. Another key initiates a new memorizing
period, cancelling previous values.
Data Interface (Option)
RS232 (for PROFIBUS see version 124.1S4)
Transmitting measurements on demand.
No configuration of parameters via Interface.
Power Supply Options
18…40 volts AC/DC (suffix U1 to model No)
85..265 volts AC/DC (suffix U2 to model No)
Power consumption approx 5 VA.
Operating Conditions
Ambient temperature 0°C … +50 °C (30 …95 °F)
Humidity max 70%, without condensation.
Insulation Category I
Complying Standards EMI according EN 610000-6.2, ..-6.4
Safety EN 61010-1
Ordering Information _ 124.100 _ __
Design Version Power Supply
C = Panel Mount U1 = 18…40 v
D = Snap-on-track U2 = 85..265 v
Data Interface
0 = none
2 = RS 232
Panel Mount Version ( C ) Snap-on-track Version ( D )
|
|