BP 340 solar module - BP Solar - #1

/ 2


catalogue search
BP 340 solar module - BP Solar
P. 01
BP 340 solar module - BP Solar
P. 02
Pages:
BP 340 solar module - BP Solar


See other catalogues for BP Solar

Text version of the page
40 Watt Photovoltaic Module

BP 340 solar module - 15873 BP 340

High-efficiency photovoltaic module using silicon nitride multicrystalline silicon cells. Performance

Rated power (P
max ) 40W Power tolerance ± 10% Nominal voltage 12V Limited Warranty
1 25 years

Configuration

J Clear universal frame and standard J-Box

Electrical Characteristics

2 3

BP 340

Maximum power (P
max ) 40W Voltage at Pmax (V
mp ) 17.3V Current at Pmax (I
mp ) 2.3A Warranted minimum P
max 36W Short-circuit current (I
sc ) 2.5A Open-circuit voltage (V
oc ) 21.8V Temperature coefficient of I
sc (0.065±0.015)%/ °C Temperature coefficient of V
oc -(80±10)mV/°C Temperature coefficient of power -(0.5±0.05)%/ °C NOCT
(Air 20°C; Sun 0.8kW/m 2 ; 47±2°C
wind 1m/s ) Maximum series fuse rating 20A Maximum system voltage 50V (U.S. NEC & IEC 61215 rating)

Mechanical Characteristics

Dimensions Length: 655mm (25.8”) Width: 537mm (21.1”) Depth: 50mm (1.97”) Weight 5.75 kg (12.7 pounds Solar Cells 36 cells (62.5mm x 125mm) in a 4x9 matrix connected in series Junction Box J-Version junction box with 4-terminal connection block; IP 65, accepts PG 13.5, M20, ˝ inch conduit, or cable fittings accepting 6-12mm diameter cable. Terminals accept 2.5 to 10mm
2 (8 to 14 AWG) wire.
th Construction Front: High-transmission 3mm (1/8 inch) tempered glass; Back: White Polyester; Encapsulant: EVA Frame Clear anodized aluminum alloy type 6063T6 Universal frame; Color: silver
1. Module Warranty: 25-year limited warranty of 80% power output; 12-year limited warranty of 90% power output; 5-year limited warranty of materials and workmanship. See your local representative for full terms of these warranties. 2. This data represents the performance of typical BP modules, and are based on measurements made in accordance with ASTM E1036 corrected to SRC (STC.) 3. During the stabilization process that occurs during the first few months of deployment, module power may decrease by approx. 1% from typical P max . BP Solar 2007 6802.0045 BP340J Rev. A 06/07

pageCatalog pdf di En 2012-05-20-15