2.0 - ELECTRICAL FEATURES
2.1 - OPERATING CONDITIONS 2.1.1 - Voltage
In their standard configuration motors are designed for 230V-50Hz supply. Upon request, motors can also be specified for 115V-60Hz or 230V-60Hz supply.
2.1.2 - Type of duty
Motor outputs listed in this catalogue refer to S1 continuous duty.
For motors operated at duties other than S1, as per Norms CEI EN 60034-1, please refer to Bonfiglioli's Technical Service for advise.
Single-phase motors have greater losses when they run idle than in full load operation. Running idle for a long period is therefore NOT recommended.
2.1.3 - Ambient temperature
Catalog ratings are relevant to 50 Hz operation, under installation conditions as specified by standards CEI EN 60034-1 (temperature between -15 °C and + 40 °C and altitude above sea level < 1000 m).
2.1.4 - Cooling
Motors are cooled by external ventilation systems (IC 411 in accordance with CEI EN 60034-6) and are equipped with a plastic radial fan suitable for both directions ofrotation.
Installation must take into account a minimum clearance of the fan cowl from the nearest wall so as to ensu­re unobstructed air circulation. This will also facilitate routine maintenance operations.
Configuration with run capacitor
SC
Single-phase motors featuring the run capacitor only feature starting torque considerably lower than rated torque (MS = 30 - 70 %MN) and are therefore only suitable for applications calling for low starting torque re­quirements.
Configuration with start and run capacitor
For applications calling for higher starting torques, motors can be supplied with starting and run capacitors
attached. In this case a starting torque MS = 140 - 170% MN will be allowed.
The starting capacitor is automatically cut off by the starter relay after approximately 1.5 seconds.
AFor letting the starting capacitor discharging allow for a minimum 6 seconds rest time before recon­necting the motor.
ÜÍ\BONFIGLIOLI
RIDUTTORI 5
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
pdf-page pdf di En 2009-01-02-09