SYMPTOM
PROBABLE CAUSE CORRECTIVE ACTION
MOTOR WILL NOT STOP WITH SPEED INPUT SET TO ZERO
Minimum speed adjustment is set too high
Turn the MIN pot{R15) CW until motor stops.
Defective Interlace Board
Replace the Interface Board.
NO SPEED ADJUSTMENT
Defective Interface Board
Replace the Interface Board.
No connection to PIN 10 on J1 of the driver
Check connections to J1, Referto Fig. 1.
Wrong settings on Analog Board
Review pages 16-22.