| | | TROUBLESHOOTING | | |
| | | |
| | | WARNING Disconnect the control from the power source before working on the control, motor, or driven equipment. | | |
| | | |
| | | Your control should not require maintenance under normal conditions. If you encounter a problem, follow the advice contained in this section. If the problem persists, contact your source of purchase or a Bodine Authorized Service Center and describe the problem in detail. Include alt the nameplate data. Do not disassemble the product unless authorized by Bodine Electric Company. Performing repairs not authorized by Bodine Electric Company or removing screws will void the Warranty. Read all applicable instruction literature provided with your control and accessories, and double-check your wiring. Verify that proper input signals have been applied to the input terminals of the Analog Board. | | |
| | | |
| | | CORRECTIVE ACTION | | |
| | | PROBABLE CAUSE | | |
| | | |
| | | |
| | | Shorted SCR, Power Bridge Replace the PC board or Varistor (V1 ) or power bridge. Control or Motor Shorted Check tor shorts and to Earth Ground repair as required. | | |
| | | CONTROL BLOWS LINE FUSE "FL" | | |
| | | |
| | | |
| | | Replace fuse. Refer to Fig. 2 for recommended luse value. Install the jumper assembly, see Fig. 1. Check to be sure that PIN 11 of J1 on driver board is 2.7 VDC above PIN 7(0 VDC), see Rg. i. Check to be sure that terminal 5 of TB2 on analog board is normally under 2VDC. Repair or replace motor. | | |
| | | Blown Line Fuse (FL) or Armature Fuse (FA) | | |
| | | MOTOR WILL NOT START | | |
| | | |
| | | |
| | | J2 Jumper Assembly is missing on the driver SCR Inhibit Function is activated | | |
| | | |
| | | Analog Interface Board inhibit latch is set | | |
| | | |
| | | Defective Motor or Worn Brushes | | |
| | | |
| | | 33 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |