| | | The Circuit Connection Diagrams in Fig. 3 show all electrical control connections. 1. Identify the Driver Board as shown in Fig. 1, and identify the fuse-holder labeled "FA" (Armature Fuse). Refer to Fig. 2 (or the label on the side of the Type-FPM control) for the proper fuse rating, and select the fuse with this rating from the bag of fuses provided. Then, install this fuse in fuse-holder "FA." 2. The line fuse, labeled "FL" in Fig. 1 and on the driver board, has been installed. Its rating is shown on the control's nameplate should it need to be replaced. 3. Next, locate the "DIP switch" on your control's driver board (Fig. 1). There are eight switch levers (numbered 1 through 8) on the "DIP switch."The "ON" positions for these levers are clearly marked on the "DIP switch." Fig. 2 identifies which of the eight levers should be set in the "ON" position, depending on the control and motor or gearmotor selected. Locate your control and motor type in Fig. 2 and then set only those levers specified in Fig. 2 to the "ON" position. Be certain that the remaining levers on the "DIP switch" are in the "OFF" position. An insulated alignment tool may be used to adjust the switch settings. | | |