Table 3 – Dip Switch Settings DIP SWITCHES FOR MOTOR MATCHING – Figure 4 shows a bank of 8 dip switches, factory-set with 4, 5, 6, and 7 ON. Set switches 1 - 7 to match the type, voltage, armature speed (not output speed of geared motor), current, and horsepower ratings on the Bodine motor nameplate per Table 3. For non- Bodine motors, or Bodine motors not listed in Table 3, identify the motor in Table 3 with the closest voltage, armature speed, current, and horsepower ratings and use those dip switch settings. Leave switch 8 OFF for 0 – 90 VDC output or switch it ON for 0 – 180 VDC output (with 230 VAC input only).

Bodine Rated Rated Armature Rated Current Rated Power Dip Switches Motor Type DC Volts Speed (rpm) (DC Amps) (HP) ON 90 1725 0.30 1/42 4,5,6,7 24A2… 130 2500 0.30 1/29 4,5,6,7 180 1725 0.13 1/49 4,6,7,8 90 1725 0.45 1/25 3,4,6,7 115 11,500 1.1 1/7 NOTE 1 24A4… 130 2500 0.45 1/17 3,4,6,7 180 1725 0.18 1/32 4,6,7,8 180 3000 0.30 1/21 3,5,6,7,8 90 1380 0.71 1/17 2,3,4,6,7 130 2000 0.71 1/12 2,3,4,6,7 33A3… 90 1725 0.71 1/17 1,6,7 130 2500 0.71 1/12 1,6,7 180 1725 0.25 1/23 4,6,7,8 90 1725 1.0 1/12 2,7 90 1725 1.8 1/8 N/A 33A5… 130 2500 1.0 1/8 2,7 130 2500 1.8 1/4 N/A 180 1725 0.41 1/14 3,4,5,6,7,8 180 3000 0.62 1/8 1,2,3,6,8 33A7… 90 1725 2.4 1/6 NOTE 2 130 2500 2.4 1/3 NOTE 2 42A3… 90 1725 1.0 1/12 2,5,7 130 2500 1.0 1/8 2,5,7 42A4… 90 1380 1.3 1/9 2,5,7 130 2000 1.3 1/6 2,5,7 90 1725 1.8 1/6 1,3,4 90 1725 2.7 1/4 NOTE 2 42A5… 130 2500 1.8 1/4 1,3,4 130 2500 2.7 1/3 NOTE 2 180 1725 0.85 1/6 3,5,8 180 3000 1.17 1/5 1,3,4,8 90 1725 2.3 1/5 1,2,3,4,5 90 1725 2.9 1/4 NOTE 2 42A7… 130 2500 2.3 1/3 1,2,3,4,5 130 2500 2.9 1/2 NOTE 2 180 1725 1.0 1/5 2,5,8 180 3000 1.5 1/4 1,2,3,4,5,8 NOTE 1: Set switches 2 and 7 ON, and turn REG trim pot fully CCW. NOTE 2: Motor’s current rating exceeds the continuous rating of the control. It may be operated at reduced load or intermittently at rated load with switches 1, 2, 3, 4, and 5 ON.

9

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
pdf-page pdf di En 2009-01-02-09