Protection against reaching through openings, dimensions for lower limbs
The values in the following table apply only to persons who are at least 14 years old. Values in mm.
Distances to prevent crushing, EN 349
A
Annex B of EN ISO 13857 describes special instances where a safety device only restricts access by a standing person. Where the risk is one of slipping - and this can never be completely excluded in the normal industrial environment - the values that it gives are not practical. Therefore we have not quoted them.
Part of the
body
Minimum distance a
Figure
Body
500
Part of the body
Figure
Opening
Safety distance
Head
300
ill
Slot
Square/ circular
e m 5 0
0
Tip of toe
M 10
0
Leg
180
5 < e m 15
1 'ft.
Toe
15 < e m 35
M 80
M 25
120
J
Foot
35 < e m 60
M 180
M 80
Foot
60 < e m 80
M 650
M 180
Toes
50
Leg (as far as the knee)
80 < e m 95
M 1100
M 650
Arm
120
95 < e m 180
M 1100
M 1100
Leg (as far as the crotch)
Hand, wrist, fist
100
180 < e m 240
Not allowed
M 1100
The coloured area shows which part of the body is restricted by the size of the opening. If a slot is < 75 mm long the safety distance can be reduced to > 50 mm.
Slots > 180 mm and square or circular openings > 240 mm permit full body access. Additional protective measures must be taken.
Finger
25
MBS