Data Sheet BenchOne Biogas
2Pages

{{requestButtons}}

Catalog excerpts

Data Sheet BenchOne Biogas - 1

The new bench top analyzer for biogas: The BenchOne Biogas a laboratory scale bench top analyzer for biogas. It measures CO2 as well as CH4 in real-time. Just connect your vessel or fermenter to the inlet of this biogas analyzer, connect the off gas line and start the measurement. In the BenchOne Biogas there are two IR sensors (one for methane and one for carbon dioxide) and also one pressure sensor to compensate pressure fluctuations automatically. This reliable device makes the gas analysis for the biogas process affordable and easy. The measuring range of this biogas analyzer is 0-50% Vol.% for CO2 and 0-100 Vol.% for CH4 and it has no interferences to humidity and hydrogen sulphide. Due to the internal heated piping, made of stainless steel, there will not be a corrosion inside the apparatus. You can see the actuals measured values at the displays. The BenchOne Biogas can be connect via analog outputs as well as via RS232 and RS485 for example to a process control system or an analysis and monitoring software for bioprocesses like the new BlueVis. As an active sampling with a pump is not needed, the BenchOne Biogas offers an independent of flow and reliable gas analysis, especially for fermenters with low gas volume. You do not need a minimum gas flow and the gas also does not need special treatment (no drying needed). Data output: 2 displays, RS232, RS485, 2x 4-20 mA, USB Mechanical connection: Swagelok for 6mm outer diameter (OD) Mesuring range: 0-50% Vol.% for CO2 and 0-100 Vol.% for CH4 Your advantages: • No minimum gas flow needed • No pumps • Pressure and temperatue compensated • Easiest installation • CO2 and CH4 measurement in one device • 2 Displays • No extra gas cooler/dryer • RS485/RS232 The BenchOne Biogas is the most convenient bench top tool for the analysis of biogas in the lab. BlueSens gas sensor GmbH Snirgelskamp 25 – 45699 Herten (Germany) Phone +49 2366 4995-500 Fax: +49 2366 4995-599 E-Mail: info@BlueSens.de

Open the catalog to page 1
Data Sheet BenchOne Biogas - 2

Data: Sensor Measuring range Measuring principle Accuracy Long-term stability** Infrared, dual wavelengths < ± .0.5 % FS* ± 5% reading General Dimensions / weight (W x H x D) Materials in contact with gas Steel 1.5471, Viton Sapphire Mechanical connection Temperature range Pressure range 1-point calibration once per month with N2 Optional full factory calibration once a year Don´t use in explosive environments! *full scale **with monthly 1-point calibration BlueSens gas sensor GmbH Snirgelskamp 25 – 45699 Herten (Germany) Phone +49 2366 4995-500 Fax: +49 2366 4995-599 E-Mail: info@BlueSens.de

Open the catalog to page 2

All BlueSens gas sensor GmbH catalogs and technical brochures

  1. Yieldmaster

    12 Pages

  2. BCP-O2

    8 Pages

  3. BlueVCount

    2 Pages

Archived catalogs

  1. BlueVary

    2 Pages

  2. REPORT 1

    36 Pages