serv-Clip
®
serv-Clip -1
for mounting on pressurized pipes
TUBE MEASURING CONNECTION Characteristics to order
SC - 1 - A - 30 >
serv-Clip type Construction type Outer diameter of pipe Tube recommendations according to the manufacturer of screwing fittings Series L 10 x 1,5 / 12 x 1,5 Series S 10 x 3,0 / 12 x 3,5 15 x 2,0 / 18 x 2,0 14 x 4,0 / 16 x 3,0 22 x 2,0 / 28 x 2,0 20 x 3,5 / 25 x 4,5 35 x 2,0 / 42 x 3,0 30 x 4,0 / 38 x 5,0 Safety instructions To ensure a correct and safe installation of the serv-Clip, please read our separate leaflet 12.B with installation instructions and a chapter on safety referring to
pressure measuring clips. The indicated measuring clips serv-Clip are exclusively for use in fluid-technical plants. The field of application is Tubes with technical oils, like hydraulic systems and lubrication oil supply or
cooling plants. Use in air and gas tubes is forbidden . We reserve ourselves the right to modifications which are useful for any further technical development. Installation of the Prior to the installation a check must take place to ensure that the outer diameter of the tube concerned and that of the selected serv-Clip serv-Clip match. It is not permitted to install a serv-Clip onto tubes that are seriously rusted or seem to be cracked. Furthermore, it is a precondition that the tube system should be laid and fixed in such a way that the serv-Clip is not affected by any additional burdens, stress and tensions. Tubes are to be laid so as to be adequately stable in relation to the operational conditions and they are to be equipped with fixed points. Then the part of the tube where the installation is to take place has to be cleaned and all paint and paint remains are to be removed. The tube should be smooth, clean and dry at this point. Then the housing, consisting of two parts, is positioned on the tube. The four housing screws are now fastened firmly. The last step is to turn the screw head to the right to the stop position, using a wrench ( without extension ). The screw head is then screwed back. Thus the connection has been made and the measuring point can be put to permanent use. tube - Tolerances of the outer diameter of the tube according to DIN 2391 10 mm 12 –30 mm 35 – 38 mm 42 mm 3/8“ ½“ :5/8“; ¾“;1“ 1 ¼“;1 ½“ -/- ∅ permitted deviation ± 0,10 mm ± 0,08 mm ± 0,15 mm ± 0,20 mm Tube recommendation for steel made serv-Clips Seamless drawn steel tubes made out of ST 35.4 material or pre-
treated basic material ST 37.4 according to DIN 1630. Condition when supplied NBA (normalizing, bright annealed) with outer tube diameter tolerances according to DIN 2391, maximum hardness: HRB 75. Construction dimensions of the serv-Clip are adapted to the tubes and tolerances according to DIN 2391. Pressure capacity P >
B 630 (9100 psi) the indications with regard to pressure and safety are based on the installation according to this data leaflet >
Bolender Tel. (+49) (0) 2331 30 639-0 Service-Tel. 0700 BKM HAGEN Maschinenkonstruktion GmbH Fax (+49) (0) 2331 30 639-11 Service-Fax 0700 SERV CLIP Sedanstr. 41 Skype MSN SERVCLIP 58089 Hagen-Germany http://www.servclip.com E-mail: sales@servclip.de 8 >