flow rate and leakage Sensor fluid-Check for hydraulic and transmission oil - BKM Bolender Maschinenkonstruktion GmbH - #1 |
|
You may also be interested in
Measurement kit, Piezoresistive pressure sensor, Sensor, Pressure sensor, Pickling line
Text version of the page
fluid-CheckSensors
Bolender Tel. (+49) (0) 2331 30 639-0
Maschinenkonstruktion GmbH Fax (+49) (0) 2331 30 639-11
Sedanstr. 41
58089 Hagen-Germany http://www.servclip.com E-mail: sales@servclip.de
18
Flow rate sensor QS
for serv-Clip® 2
- No need cutting pipelines -
RECOMMENDED MEASURING RANGES
Range
OD-Pipe
in mm
Tube
Inch
(OD)
Pipe
Inch
(ID)
ID-Pipe
in mm
Recommended
Measuring range
l/min
001 12 3/8 - 8 - 10 0,5 - 38
002 14 -15 1/2 1/4 11 - 12 0,7 - 52
003 16 - 18 5/8 3/8 12 - 14 0,9 - 75
004 20 - 22 3/4 1/2 15 - 17 1,4 - 110
005 25 - 28 1 3/4 19 - 22 2,2 - 190
006 30 - 35 11/4 1 23 - 29 4,0 - 320
007 38 - 42 11/2 11/4 30 - 36 6,0 - 500
008 - - - No calibrated
Calibration is adjusted only for a measuring range
What can I measure? Hydraulic and gear oil
With the QS flow rate sensor (up to 600 l/min):
• Monitoring flow rate and wear of pumps
• Operability of accumulators
• Filter transmittance
• Heat exchangers
• Nozzle flow rate
• Speed of hydraulic motors
• Lubrication lack of gears
Qualities: stainless steel housing (QS-1-B-008)
and with PBT housing (QS-2-B-008)
Leakages detection? Our solution LS Sensor (Page 19)
Mobile Measurement kit FM-1-B for sensors (Page 22)
Description
The flow rate sensor QS fluid-Check® was developed for monitoring hydraulic
systems. Needed time for measuring 9 seconds.
The flow rate sensor can be used with the pipe measuring point serv-Clip® for
steel pipelines from 12 mm x 1,5 mm up to 5,5 mm wall thickness.
Exception: with 12x2 mm use no possible
For pipes from 3” (88,9 mm) and wall thickness from 6 mm can be used the
welding adaptor SC-XE-607.
serv-Clip Type 2 special needles for stainless steel pipelines up to 5,5 mm
wall thickness can be provided upon request.
The measurement system is based on the calorimetric principle, which provides
a direct measurement of the flow velocity in l/min rather than measuring the
volume flow. It means sensor head has an intern thermo element and a heating
(calorimetric principal). The running oil temperature will be measured. The sensor
head temperature raises at 2°C. The time for this will be measured and the flow
rate will be calculated. The measuring cycle takes 5 seconds.
Calibration service (please see chart of the left side)
For the ID-pipe with the wished measuring range from/to in l/min.
With your instructions for calibration you get a data sheet with curves mA in l/min.
For a quotation please let us know :
1) (for SC) outer diameter and wall thickness of the pipeline in mm
2) (for calibration) wished quantity min/max in Liter/Minutes.
We have a test bench for calibrations up to 220 L/min only.
You can calibrate the product by yourself if you count on a test bench.
Installation with serv-Clip® 2
The patented measuring connector sc-2-... was developed for installation on
pressureless hydraulic pipes.
After installation, the measuring connection can continuously be used, supporting
operating pressures of up to 630 bar.
The measuring connection sc-2-... comes pre-mounted, including measurement
coupling and needle, and is mounted as described in the corresponding
installation instructions.
To install the flow rate sensor, the created 2 mm hole must be widened.
In the first step, the short needle of the measurement coupling is screwed
down completely - without applying much force - until the stop is reached.
Then it is unscrewed again. In the second step, the long needle is screwed
down completely and unscrewed again, too.
Now the flow rate sensor can be screwed into the serv-Clip®. The measuring
connection is completely tight and is ready for continuous use.
Using the serv-Clip® sc-2-... , the flow rate sensor can be installed easily, quickly
and safely even by non-technical staff. The whole process takes a few minutes
only. No special tools are required for the installation of the serv-Clip® and the
flow rate sensor.
The system is completely tight, preventing any contamination of the hydraulic oil
and ensuring sustained operational safety. The measuring connections are
continuously available for measurement applications.
Special instructions for stainless steel up to 4 mm wall thickness with SC-2
can be provided.
Specifications
Measuring range 0,05 ... 8 Meter/Second
Flow rate up to 600 l/min, depending on ID
Pressure 630 bar (9100 psi)
Temperature -20…80°C
Threaded coupling G 3/8“
Accuracy +/- 2%
Output signal 4…20 mA (analogue)
Power supply 24 V DC +/- 10%; 150mA
Connection M12 Universalstecksystem
Setting Per Micro button
Display 6 LED lights
Protection mode IP 65
Sensor head stainless steel 1.4571
Housing Stainless steel or PBT
|
|