Radiation Interference Discrimination
100
75
50
level
25
fill
0
-25
-50
-channel 1
s"
-channel 2
7
\
;—^
' /
y /
/
The Nuclide makes the difference
The nuclides employed for weld inspections are different from the ones typically used in radiometric level gauges. Berthold Technologies' patented1' level system LB440-RID exploits this difference to suppress the influence of interference radiation on the measurement. Nearly all weld or material inspections are performed with Iridium-192 or Selenium-75 sources. The energy of their radiation is low (<600 keV) compared to Co-60 (>1000 keV), commonly used in level gauges. In the detector, the radiation generates voltage pulses - their pulse height depends on the energy of the impacting radiation.
0 30 60 90
time [sec]
detector, the evaluation unit switches over to channel 2 and in this manner continues to accurately determine the fill level in the vessel.
With LB440-RID, the problem of weld inspections is considerably reduced. You have full and accurate information on your process - continuously! LB440-RID is already being successfully operated in many plants world-wide.
Get RID of your problems
All continuous level measurements employing rod detectors or the SuperSens point detector can be equipped with the patented1' Radiation I nterference Discrimination LB440-RID. The system works only with Co-60 sources -the energy of the Cs-137 radiation (660 keV) is too close to the energy of sources commonly used in weld inspections to be reliably discriminated. Existing Berthold Technologies equipment can be easily upgraded to include the RID technology.
1)US patent No.6,753,532 B2 European patent pending
200
150
J/J CD
-I—i -t—i
8
100
50
0
0
200 400 600 800 1000
pulse height [mV]
1200
Pulses from weld inspection sources do not exceed a certain height and are thus not recorded in channel 2.
Always in control
In normal operation, the vessel level is detected from the count rate in channel 1. If interference radiation is registered by the