Chemical Strengthening - Berliner Glas KGaA Herbert Kubatz GmbH & Co. - #2 |
|
You may also be interested in
Optical component, Cylindrical lens, Light source, Mirror, Measuring device
Text version of the page
Berliner Glas KGaA Herbert Kubatz GmbH & Co • Waldkraiburger Str. 5 • D-12347 Berlin
techglas@berlinerglas.de • Phone: +49 30 60905-0 • Fax: +49 30 60905-100
www.berlinerglas.com
Chemical strengthening e0407
Chem. strengthened glass
Untreated glass
Impact resistance
(with ball drop test, 150,7 g/ height
1 m)
4 - 10 Joule (depending on conditions
of test)
1 - 2 Joule
(1 Joule = 1 N*m)
Flexibility strength ó bB:
(similar to pr EN 12337) 150 N/mm² 50 N/mm²
Resistance to temperature
(according to DIN 52313)
350°C for 1 mm glass
300°C for 2 mm glass
270°C for 3 mm glass
250°C for 4 mm glass
170°C for 1 mm glass
130°C for 2 mm glass
120°C for 3 mm glass
100°C for 4 mm glass
Vicker hardness 626 HV0,2/15 550 HV 0,2/15
Max. application temperature
300°C
(above 300°C the chemical
hardening can be reduced or lost)
450°C
Comparison of properties of chemically strengthened and of untreated
glass
The above data are merely guidelines. In exceptional cases we recommend tests under the relevant operating conditions. All
other physical and chemical properties of the glass are minimally affected.
Quality Assurance
Maintenance of the process parameters, temperature and duration of toughening is electronically controlled, monitored and
documented by records. Regular analysis of the salt bath guarantees the quality of the hardening. Each lot is tested for the
degree of penetration and surface stress. Our chemically toughened glass is reduced according to pr EN 12337.
Notes
The edges of all chemically toughened glass should be chamfered. After chemical hardening no further edge treatment is
possible. Later cutting will be possible with a reduction of the edge resistance stability. On request we mark the glass “BGÞ
CG” for “chemically toughened”. Chemically toughened glass can subsequently be printed or coated.
Measuring instruments for quality assurance
Gloss BYK Gardner Glossmaster, Haze-Guard Plus
Roughness Perthometer, White light Interferometer
Transmission and reflection Spectrometer
Outlines Smartscope, optical 3D- measurement
Layer Resistance Climatic chamber, abrasion test
Cleanliness Dark field illuminator
Flatness Interferometer
Surface defects/inclusions/edge chips Profile projector, digital microscope
|
|