Hi-Flow® 300G
Fiberglass-Reinforced, Phase Change Thermal Interface Material
TYPICAL PROPERTIES OF HI-FLOW 300G
PROPERTY
IMPERIAL VALUE
METRIC VALUE
TEST METHOD
Color
Green
Green
Visual
Reinforcement Carrier
Fiberglass
Fiberglass
Thickness (inch) / (mm)
0.005
0.127
ASTM D374
Elongation (%45° to Warp and Fill)
40
40
ASTM D882A
Tensile Strength (psi) / (MPa)
400
3
ASTM D882A
Continuous Use Temp (°F) / (°C)
212
I00
Phase Change Temp (°F) / (°C)
131
55
ASTM 3418
ELECTRICAL
Dielectric Breakdown Voltage (Vac)
300
300
ASTM DI49
Dielectric Constant (I000 Hz)
3.5
3.5
ASTM DI50
Volume Resistivity (Ohm-meter)
I08
I08
ASTM D257
Flame Rating
V-O
V-O
U.L. 94
THERMAL
Thermal Conductivity (W/m-K) (I)
1.6
I.6
ASTM D5470
THERMAL PERFORMANCE vs PRESSURE
Pressure (psi)
10
25 50
100 200
TO-220 Thermal Performance (°C/W)
0.96
0.92 0.88
0.85 0.84
Thermal Impedance (°C-in2/W) (2)
0.27
0.20 0.I6
0.I5 0.I4
1) This is the measured thermal conductivity of the Hi-Flow coating.It represents one conducting layer in a three-layer laminate.The Hi-Flow coatings are phase change compounds.These layers will respond to heat and pressure induced stresses.The overall conductivity of the material in post-phase change, thin film products is highly dependent upon the heat and pressure applied.This characteristic is not accounted for in ASTM D5470.Please contact Bergquist Product Management if additional specifications are required.
2) The ASTM D5470 test fixture was used and the test sample was conditioned at 70°C prior to test.The recorded value includes interfacial thermal resistance.These values are provided for reference only.Actual application performance is directly related to the surface roughness,flatness and pressure applied.
Features and Benefits
• Thermal impedance: 0.20°C-in2/W (@25 psi)
• Will not drip or run like grease
• Phase change compound coated on a fiberglass carrier
Hi-Flow 300G consists of a thermally conductive 55°C phase change compound coated on a fiberglass web. Hi-Flow 300G is designed as a thermal interface material between a computer processor and a heat sink
Above the phase change temperature, Hi-Flow 300G wets-out the thermal interface surfaces and flows to produce low thermal impedance.The material requires pressure of the assembly to cause flow. Hi-Flow 300G will not drip or run like grease.
Application Methods
1. Hand-apply to 40°- 50°C heat sinkThe heat sink is heated in an oven or by a heat gun
to between 40°- 50°C allowing the Hi-Flow
300G pad to be applied like an adhesive pad. The heat sink is then cooled to room temperature and packaged.
2. Hand-apply to 20°- 35°C heat sink Hi-Flow 300G can be applied to a room temperature heat sink with the assistance of a foam rollerThe pad is positioned on the heat sink and a hand roller is used to apply pressure of 30 psi.
3. Automated equipment with 30 psi pressure. A pick-and-place automated dispensing unit can be used to apply Hi-Flow 300G to a room temperature heat sinkThe placement head should have a soft silicone rubber pad, and apply 30 psi pressure to the pad on transfer to the 20°- 35°C heat sink.
О _i
Typical Applications Include:
• Computer and peripherals
• As a thermal interface where bare die is exposed and needs to be heat sinked
Configurations Available:
• Sheet form, die-cut parts and roll form
• With or without pressure sensitive adhesive
Building a Part Number
Standard Options
H example
HF300G
NA = Selected standard option. If not selecting a standard option, insert company name, drawing number, and revision level.
___= Standard configuration dash number,
1012 = 10" x 12" sheets, 10/250 = 10" x 250' rolls, or 00 = custom configuration
AC = Adhesive, one side 00 = No adhesive
Standard thicknesses available: 0.005"
<
О
<D Si
О SI
0 SI
- HF300G = Hi-Flow 300G Phase Change Material
Note: To build a part number, visit our website at www.bergquistcompany.com.