Coil voltages for AC operated contactors
Type-suffix for coil-types K6/.. to K45/...
for contactor-types K3-07.. to K3-74
Type-suffix for coil-types K85/... and K110/...
for contactor-types K85 to K110
Suffix
to to
contactor coil
Voltage Marking Rated Control Voltage U
Suffix to
Voltage Marking Rated Control Voltage U
to
at the coil for 50Hz V
for 60Hz V
range
for 50Hz
min. max.
VV
for 60Hz
min. max.
VV
contactor coil
at the coil
for 50Hz V
range for for 50Hz 60Hz min. max.
VVV
for 60Hz
min. max.
VV
type
type
type
type
6 41.6 6 6 6,6 6,6 7,3
6,6 41.6,6 6,6 6,6 7,3 7,3 8
7,3 41.7,3 7,3 7,3 8 8 9
20
4.20
20
24
20
22
24
26
24
4.24
24
24
27
29
32
42
4.42
42
42
47
50
56
8
41.8
8
9
10
9
41.9
9
9
10
10
11
10
41.10
10
10
11
11
12
110 4.110 110-120 110 122 132 146
230 4.230 220-240 277 220 240 264 288
400 4.400 380-415 460-480 380 415 455 498
11
41.11
11
12
11
12
12
13,2
12
41.12
12
12
13,2
13,2
14,5
13,2
41.13
13,2
13,2
14,5
14,5
16
14,5
41.14
14,5
14,5
16
16
18
16
41.16
16
16
18
18
20
18
41.18
18
18
20
20
22
20
41.20
20
20
22
22
24
24
4.24
24
24
22
24
24
27
25
41.25
25
24
27
27
30
27
41.27
27
32
27
30
30
33
31
41.32
32
36
30
33
33
36
33
41.33
36
36
33
36
36
39
36
41.36
36
42
36
39
39
42
40
41.40
42
42
39
42
42
47
42
4.42
42
48
42
47
47
52
48
41.48
48
48
44
48
48
52
55
41.55
55
60
52
58
58
65
60
41.60
60
58
65
65
72
65
41.65
65
65
72
72
80
75
41.75
75
72
80
80
90
85
41.85
85
80
90
90
100
90
41.90
100
100
90
100
100
110
110
4.110
110
110-120
100
110
110
122
115
41.115
115
125
110
122
122
135
127
41.127
127
122
135
135
150
140
41.140
140
135
150
150
165
150
41.150
150
150
165
165
180
165
41.165
165
180-208
165
180
180
208
180
41.180
180-210
200-240
180
210
200
240
200
41.200
200-2301'
220-240
200
2301'
220
240
Type-suffix
for coil-types K3-1200/..
for contactor-types K3-1000.. to K3-1200..
110
4.110
110-115 -
110 115
110
115
230
4.230
220-230 -
220 230
220
230
400
4.400
380-400 -
380 400
380
400
440
4.440
440 -
440 440
440
440
Coil voltages for AC and DC operated contactors
Type-suffix for coil-types K3-115/.. to K3-860/..
for contactor-types K3-90.. to K3-860..
Suffix
Voltage Marking
Rated Control Voltage Us
to
to
contactor
coil
at the coil
range
type
type
for
for
for 50Hz
for 60Hz
50/60Hz
DC
min. max.
min. max.
V
V
VV
VV
24
4.24
24
24
22 24
22 24
48
4.48
48
48
44 48
44 48
110
4.110
110-120
110
110 120
110 120
230
4.230
220-240
220
220 240
220 240
400
4.400
380-415
-
380 415
380 415
230
4.230
220-240
230-264
220
240
230
264
254
41.254
254
277
240
264
264
290
270
41.270
270
264
290
290
315
300
41.300
300
290
315
315
345
320
41.320
320
315
345
345
380
345
41.345
345-4001' 380-4401'
345
4001'
380
4401'
400
4.400
380-415
400-440
380
415
400
460
415
41.415
415-440
440-480
400
440
440
480
440
41.440
440-480
480-500
440
480
480
530
480
41.480
480-500
530-580
480
530
530
580
500
41.500
500-550
550-600
500
550
550
600
550
41.550
550-600
550
600
Standard voltages in bold type letters
Operating range of magnet-coils: 0,85 x Us (min. value of rated control voltage) up to 1,1 x Us (max. value of rated control voltage)
1) Operating range of magnet-coils: 0,85 x Us (min. value of rated control voltage) up to 1,05 x Us (max. value of rated control voltage)
EU benedict