Contactors, Motor-Starters - BENEDIKT & JÄGER - #2

/ 124


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
P. 37
P. 38
P. 39
P. 40
P. 41
P. 42
P. 43
P. 44
P. 45
P. 46
P. 47
P. 48
P. 49
P. 50


See other catalogues for BENEDIKT & JÄGER
You may also be interested in

Switch, Electronic starter, Starter, Switchgear, Motor starter


Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:9.00pt "Arial", sans-serif; } .font5 { font:10.00pt "Arial", sans-serif; } .font6 { font:11.00pt "Arial", sans-serif; } .font7 { font:20.00pt "Arial", sans-serif; } .font8 { font:6.00pt "Arial Black", sans-serif; } .font9 { font:7.00pt "Arial Black", sans-serif; } .font10 { font:7.00pt "Lucida Sans Unicode", sans-serif; } General Test Authorities, Registration Mark, Approvals Low voltage switchgear from Benedict GmbH is built and tested to national and international specifications. All devices suit all important specifications without any test obligation, like VDE, BS and also relative to IEC Recommendations and to European Standards like IEC 947 and EN 60947. It is for this reason of our Low voltage switchgear is used all over the world. In order to provide special versions, limitations to the max. voltages, currents and power ratings or special markings are sometimes necessary. Quality Control System Since November 1991 Benedict GmbH has been certified according to the quality control system ÔNORM EN ISO 29001. The target of the ISO­certification is, to grant the customer the quality of the performance of his supplier, who is audited in accordance with this standard. CE-Marking £ £ The manufacturer has to sign his products with the CE-Marking. With the CE-Marking the manufacturer confirms the accordance with the different EEC Directives. The CE-Marking is absolutely necessary to sell the products in the EEC. Below you find the EEC Directives concerning our products. Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS + WEEE 2002/95/EC + "002/96/EC Country North America Switzerland Russia State deputy or private examination (state admitted) UL Canada, USA SEV GOST Label marking of examination boards c(5l)us Listed c^Xus Component © Duty of approvals all switchgear all switchgear all switchgear Explanations for choice and supply of low voltage switchgear in Canada and USA Marking of auxiliary contacts At several devices in UL-data are two voltages for auxiliary contacts mentioned (e. g.: 600 volts at same potential, 150 volts at different potentials). That means, if the voltage is higher than 150 volts, the control voltage applied to input terminals must be at the same potential. Low voltage switchgear for auxiliary circuits (e. g. contactor relays, control units, auxiliary contacts in general) usually approved for "Heavy Duty" or "Standard Duty" UL and besides these marked with the admissible max. voltage or with short codes (see table). Marking of Max. rated values per pole Contact auxiliary contacts Voltage Current Cont. Rating according to Make Break Current Code CSA and UL V A A A Designation Heavy Duty AC 120 60 6 10 A150 (HD or HVY DTY) AC 240 30 3 10 A300 AC 480 15 1,5 10 A600 AC 600 12 1,2 10 A600 DC 125 2,2 2,2 10 N150 DC 250 1,1 1,1 10 N300 DC 600 0,4 0,4 10 N600 Standard Duty AC 120 30 3 5 B150 (SD or STD DTY) AC 240 15 1,5 5 B300 AC 480 7,5 0,75 5 B600 AC 600 6 0,6 5 B600 DC 125 1,1 1,1 5 P150 DC 250 0,55 0,55 5 P300 DC 600 0,2 0,2 5 P600 AC 120 15 1,5 2,5 C150 AC 240 7,5 0,75 2,5 C300 AC 480 3,75 0,375 2,5 C600 AC 600 3 0,3 2,5 C600 DC 125 0,55 0,55 2,5 Q150 DC 250 0,27 0,27 2,5 Q300 DC 600 0,1 0,1 2,5 Q600 AC 120 3,6 0,6 1 D150 AC 240 1,8 0,3 1 D300 DC 125 0,22 0,22 1 R150 DC 250 0,11 0,11 1 R300 - AC 120 1,8 0,3 0,5 E150 Discernment at UL-Standards Recognized Component Industrial Control Equipment UL issues yellow "Guide cards" with Guide- and File-No. Listed Industrial Control Equipment UL issues white "Guide cards" with Guide- and File-No. Devices have permission to be marked with on the label Q\ Devices have to be marked with the "UL-Listing Mark" t@us Devices as components approved for "factory wiring": devices for employment in control panels, when they are selected, mounted and wired according to the charging conditions by skilled worker. Devices approved for "field wiring", a) devices for employment in control panels, when they are mounted and wired by skilled worker. b) devices for retail in USA Valid UL-Standards: UL 508 "Standard for Industrial Control Equipment" (partly limited) Valid UL-Standards: UL 508 "Standard for Industrial Control Equipment" (unlimited) Are devices approved as "Listed Equipment" t(J^us the approval is also valid for using as "Recognized Component" c^^us 2 D677E ggBENEDICT

pageCatalog pdf di En 2012-02-07-16