Remote alarm indicator and operator panels

Open the catalog to page 1
TM Series Alarm and control panels - 2

Remote alarm indicator and operator panels Product description In terms of the human/machine interface, alarm indicator and operator panels play a crucial role. Their task is to take system information and transform it into clear instructions, particularly in the event of critical operating situations. The flexible TM800 panels provide solutions that meet the requirements of modern medical facilities as well as industrial and functional buildings. They are used for • indication and visualization of operating status and alarm messages; • central operation and parameter setting of BMS bus...

Open the catalog to page 2
TM Series Alarm and control panels - 3

Alarm indicator and operator panel TM800 History memory Digital inputs and outputs as well as relay outputs are provided for the control and indication of different technical equipment. The digital inputs are designed for a voltage of AC /DC 0…30 V, but in practical application the messages often arrive as potential-free contacts, this voltage is supplied by the integrated power supply unit. The performance of the alarm contact at the digital input (N/O contact or N/C contact) can be assigned via this PC software. That means that subsequent modifications of the contact performance do not...

Open the catalog to page 3
TM Series Alarm and control panels - 4

Alarm indicator and operator panel TM800 Example of the categorization into internal and external bus devices 1 - xternal BMS subsystems: All internal BMS subsystems inteE grated into a higher-level BMS system, e.g. for the central technical control room. 2 - nternal BMS subsystems: For all BMS components within one I section, e.g. operating theatre section, intensive care unit 3 - Bus devices 1…30 (99) 4 - Bus devices 1…30 (150) Communication The alarm indicator and operator panels of the TM800 series and the changeover and monitoring modules of the MEDICS series (UFC, UMC, LFC …) can be...

Open the catalog to page 4
TM Series Alarm and control panels - 5

Alarm indicator and operator panel TM800 Operating and display elements – Basic version Mechanical design The design of the alarm indicator and operator panels is based on the individual customer requirements in terms of interior design and the architect's and constructor's needs. The following basic versions of alarm indicator and operator panels are available: • Flush-mounting type enclosure with bezel frame • Flush-mounting type enclosure with mounting frame • Surface-mounting type enclosure with a frame of anodized aluminium 1 - ED „NORMAL“: Power On indicator, green L (only lights up...

Open the catalog to page 5
TM Series Alarm and control panels - 6

Alarm indicator and operator panel TM800 Flush-mounting type and surface-mounting type enclosures for alarm indicator and operator panels AP version Surface-mounting enclosure (AP) made of anodized aluminium suitable for both pure surface mounting or for partially recessed mounting. Mounting depth: 90, 150 or 210 mm Features: • Buckling resistant plastic enclosure for flush-mounting or anodized aluminium frame for surface mounting. • seal against ingress of liquids into the A panel (IP54). • Easy to install by fixing the front plate to rugged hinges. • The front plate can be fixed without...

Open the catalog to page 6
TM Series Alarm and control panels - 7

Alarm indicator and operator panel TM800 Wiring diagram I/O module BMI8/8 Wiring diagram I/O modules BMI8/4 with BMI0/4 5 1 - X3 Connector for connecting additional I/O modules and connection to the display module 2 - S1 DIP switch for address setting. 3 - IN1…8 Digital inputs 1…8. The digital inputs either have to be activated via potential-free contacts or via voltage signals. 4 - V11…V18 Alarm LEDs, light up when voltage is connected to the associated digital input. Input Alarm LED IN1 V11 IN2 V12 IN3 V13 IN4 V14 5 - 11…84 Open-collector output for activating LEDs, relays etc. 6 -...

Open the catalog to page 7
TM Series Alarm and control panels - 8

Alarm indicator and operator panel TM800 Example of different TM800 alarm indicator and operator panel versions Grid dimensions approx. 150 x 150 mm

Open the catalog to page 8
TM Series Alarm and control panels - 9

Alarm indicator and operator panel TM800 Example of different TM800 alarm indicator and operator panel versions Grid dimensions approx. 150 x 150 mm

Open the catalog to page 9
TM Series Alarm and control panels - 10

Alarm indicator and operator panel TM800 Example of panel design 3 A - Rear of the front plate B - Mounting plate, installed in the lower part of the enclosure C - I2C bus is used for communication between the modules BM800 (resp. BM400) and the operating and display pcbs BI800. The terminals of the two I2C must not be interchanged! D - I2C bus, is used for communication between the modules BM800 (resp. BM400) and the I/O modules BMI8/8, BMI8/4 and BMI0/4. The terminals of the two I2C buses must not be interchanged! 1 - erminal board for connection to the internal and external T BMS bus...

Open the catalog to page 10
TM Series Alarm and control panels - 11

Alarm indicator and operator panel TM800 Technical data Insulation coordination acc. to IEC 60664-1 Operating and display pcbs and I/O module Rated insulation voltage AC 250 V Rated impulse voltage/pollution degree 4 kV/3 Supply voltage TM800 via integrated power supply unit, data depending on the type BI800 operating and display pcbs: Max. number of illuminated pushbuttons Buttons/alarm LEDs per panel Power consumption I/O module: Maximum number of inputs and outputs BM800 module Supply voltage US AC/DC 24 V Frequency range of US AC 40…60 Hz / DC Operating range US AC 18…28/DC 19…30 V...

Open the catalog to page 11
TM Series Alarm and control panels - 12

Dimension diagramm Dimensions in mm BMI 8/8 Bender GmbH & Co. KG P.O. Box 1161 • 35301 Gruenberg • Germany Londorfer Strasse 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-Mail: info@bender.de • www.bender.de BENDER Group TM800_D00165_00_D_XXEN / 12.2014 / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the version that was valid at the time of printi

Open the catalog to page 12

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages