Isolating transformer ES710 - 1

Isolating transformer ES710 Single-phase isolating transformers for the design of medical IT systems Also available as energy-efficient Green Line (GL) edition

Open the catalog to page 1
Isolating transformer ES710 - 2

Single-phase isolating transformers for the design of medical IT systems Application and description The transformers of the ES710 series have reinforced insulation and comply with the requirements of IEC 61558-1/DIN EN 61558-1 (VDE 0570-1) and IEC 61558-2-15/DIN EN 61558-2-15 (VDE 0570-2-15). In addition, the transformers comply with the requirements of IEC 60364-7-710/DIN VDE 0100-710 (VDE 0100-710) for IT systems in medical locations. The windings are galvanically isolated. In order to minimize electrical interferences, an electrostatic screen is installed between the primary and...

Open the catalog to page 2
Isolating transformer ES710 - 3

Nameplate ES: single-phase isolating transformer DS: three-phase isolating transformer Nominal power Type series without K LG SK2 S S-GL SN-GL Wiring diagram standard terminals on top horizontal position encapsulation according to protection class II terminals on top side end terminals front side (energy efficient) terminals front side, low type of construction (energy efficient) Terminal diagram SK2 series Standard, K series, LG series, S series, S-GL series, SN-GL series Connection properties Type Input terminals flexible/rigid Screen winding flexible/rigid Control terminals...

Open the catalog to page 3
Isolating transformer ES710 - 4

Dimension diagram/type of construction Standard SK2 series S series Dimension B is the depth incl. terminals Dimension E is the depth incl. terminals

Open the catalog to page 4
Isolating transformer ES710 - 5

Ordering information SN-GL series

Open the catalog to page 5
Isolating transformer ES710 - 6

Technical data Type Power/voltages/currents Rated power Rated frequency Rated input voltage Rated input current Rated output voltage Rated output current Inrush current IE Inrush current IE GL version Leakage current No-load input current i0 No-load input current i0 GL version No-load output voltage u0 Short-circuit voltage uk Environmental conditions Ambient temperature No-load temperature rise Full-load temperature rise Noise level (under no-load conditions and nominal load) Other Insulation classification ta40/B ta40/B ta40/B ta40/B ta40/B ta40/B Degree of protection IP00 IP00 IP00 IP00...

Open the catalog to page 6
Isolating transformer ES710 - 7

Green Line transformer (energy efficient version) – High degree of energy saving over the life time (16 years AfA) (German AfA table for deprecation of wear and tear) Purchase price + energy consumption EUR This general illustration is based on calculations of the transformer’s energy consumption while energy costs remained constant at 13.4 ct/kWh (source: first energy) for 16 years. The wide variety of bandwidths result from the different transformer capacities. Afa = Deprecation of wear and tear = Standard version = GL version (Green Line) n = A higher purchase price of approx. 15-20% ● =...

Open the catalog to page 7
Isolating transformer ES710 - 8

BENDER Group ES710_D00109_03_D_XXEN / 10.2016 / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the version that was valid at the time of printing. Bender GmbH & Co. KG P.O. Box 1161 • 35301 Gruenberg • Germany Londorfer Strasse 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-Mail: info@bender.de • w

Open the catalog to page 8

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages